id: "BEF-2026-09-14-CLEVO-002"
|
|
|
|
organization: "Beffroi"
|
|
|
|
title: "System Stability Investigation — Storage / Firmware Follow-up"
|
|
subtitle: "PC Specialist / Clevo — exhaustive diagnostic record and current assessment"
|
|
|
|
report_type: technical
|
|
theme: default
|
|
|
|
status: "open"
|
|
severity: "high"
|
|
|
|
metadata:
|
|
Date: "2026-09-14"
|
|
Device: "DESKTOP-SAU019H"
|
|
Model: "PC Specialist / Clevo NH5x_NH7x_HHx_HJx_HKx"
|
|
Motherboard: "CLEVO NHxxHJHK"
|
|
BIOS: "Insyde 1.07.07TPCS1 — 2021-09-16"
|
|
CPU: "Intel Core i7-11800H"
|
|
Memory: "16 GB"
|
|
GPU: "Intel UHD Graphics + NVIDIA GeForce GTX 1650"
|
|
OS: "Windows 11 Pro — image version 10.0.26200.9168"
|
|
SATAStorage: "128GB PCS 2.5-inch SSD — serial U9DI16295T"
|
|
NVMeStorage: "1TB PCS PCIe M.2 SSD — Silicon Motion NVMe controller PCI VEN_126F DEV_2263"
|
|
Author: "Maximilien Rigaut"
|
|
Purpose: "Continuation and consolidation of the 2026-09-04 Clevo stability investigation"
|
|
|
|
summary: >
|
|
The investigation of DESKTOP-SAU019H was resumed on 2026-09-14 after earlier
|
|
hard freezes, shutdown anomalies, an NVRAM-reset firmware warning, TPM /
|
|
Measured Boot errors and repeated NVMe controller errors. Fast Startup was
|
|
disabled by disabling hibernation. DISM successfully repaired the Windows
|
|
component store and SFC found and repaired protected system-file corruption;
|
|
a subsequent SFC scan after restart reported no remaining integrity
|
|
violations. Storage enumeration before restart exposed only the 128 GB SATA
|
|
SSD through Get-Disk and Get-PhysicalDisk, while the 1 TB NVMe remained known
|
|
to Plug and Play. After restart, Windows positively enumerated the 1 TB PCS
|
|
PCIe M.2 SSD and its Standard NVM Express Controller as present and working
|
|
properly, with the controller linked at PCIe Gen3 x4, but Get-Disk still
|
|
exposed only the 128 GB SATA SSD. A new stornvme Event 11 occurred at
|
|
16:23:21 on 2026-09-14, reporting a controller error on \Device\RaidPort2.
|
|
Historical Event 129 resets and Event 11 controller errors against the same
|
|
RaidPort2 are present on 2026-09-04 and repeatedly as far back as March 2026.
|
|
The BIOS menus inspected during this session did not list the 1 TB NVMe/SATA
|
|
device. The strongest current lead is therefore an intermittent or partial
|
|
failure somewhere in the 1 TB NVMe storage path: the SSD itself, its M.2
|
|
connection, PCIe link / slot, controller behaviour, firmware interaction or
|
|
power delivery. A failing SSD is not yet conclusively proven. The NVRAM /
|
|
CMOS issue remains a separate open diagnostic track.
|
|
|
|
timeline:
|
|
- time: "2026-09-04 ~15:21"
|
|
event: "NVMe controller error"
|
|
notes: >
|
|
stornvme Event 11 reported a controller error on \Device\RaidPort2.
|
|
|
|
- time: "2026-09-04 ~16:30"
|
|
event: "Firmware / NVRAM warning"
|
|
notes: >
|
|
Firmware displayed a first-boot or NVRAM-reset-condition warning.
|
|
|
|
- time: "2026-09-04 ~16:32"
|
|
event: "TPM / Measured Boot failure"
|
|
notes: >
|
|
TPM-WMI Event 1040 reported a critical pre-attestation health-check
|
|
failure and referenced a MeasuredBoot diagnostic JSON file.
|
|
|
|
- time: "2026-09-04 ~16:44"
|
|
event: "Second confirmed NVMe controller error"
|
|
notes: >
|
|
stornvme Event 11 again reported a controller error on
|
|
\Device\RaidPort2.
|
|
|
|
- time: "2026-09-04 ~16:53"
|
|
event: "Normal shutdown failure"
|
|
notes: >
|
|
Windows shutdown hung and a forced power-off was required.
|
|
|
|
- time: "2026-09-04 later"
|
|
event: "Restart test"
|
|
notes: >
|
|
A normal Windows restart completed successfully.
|
|
|
|
- time: "2026-09-04 later"
|
|
event: "Full-shutdown test bypassing Fast Startup"
|
|
notes: >
|
|
A full shutdown completed normally when Fast Startup was bypassed.
|
|
|
|
- time: "2026-09-04 <17:23"
|
|
event: "Hard freeze"
|
|
notes: >
|
|
A system freeze occurred before further configuration changes.
|
|
|
|
- time: "2026-09-04 ~17:25"
|
|
event: "Second hard freeze"
|
|
notes: >
|
|
A second freeze / hang was observed.
|
|
|
|
- time: "2026-09-14 before storage retest"
|
|
event: "Fast Startup disabled"
|
|
notes: >
|
|
powercfg /h off completed without error. Hibernation was disabled,
|
|
which also disables Windows Fast Startup.
|
|
|
|
- time: "2026-09-14 before storage retest"
|
|
event: "DISM CheckHealth syntax attempt"
|
|
notes: >
|
|
DISM /CheckHealth returned Error 87 because /Online /Cleanup-Image
|
|
were omitted. This was a command syntax issue and not a diagnostic
|
|
failure.
|
|
|
|
- time: "2026-09-14 before storage retest"
|
|
event: "DISM component-store repair"
|
|
notes: >
|
|
DISM /Online /Cleanup-Image /RestoreHealth completed at 100 percent.
|
|
DISM reported that the restore operation and overall operation
|
|
completed successfully.
|
|
|
|
- time: "2026-09-14 before storage retest"
|
|
event: "SFC system-file repair"
|
|
notes: >
|
|
sfc /scannow found corrupt files and successfully repaired them.
|
|
|
|
- time: "2026-09-14 before restart"
|
|
event: "Initial disk inventory"
|
|
notes: >
|
|
Get-Disk exposed only Disk 0, the 128GB PCS 2.5-inch SATA SSD,
|
|
Online and Healthy. The 1 TB NVMe was absent from Get-Disk.
|
|
|
|
- time: "2026-09-14 before restart"
|
|
event: "Initial physical-disk inventory"
|
|
notes: >
|
|
Get-PhysicalDisk exposed only the 128GB PCS 2.5-inch SATA SSD,
|
|
Healthy / OK. The 1 TB NVMe was absent from this storage-provider view.
|
|
|
|
- time: "2026-09-14 before restart"
|
|
event: "PnP controller inventory"
|
|
notes: >
|
|
A Standard NVM Express Controller with hardware ID PCI\VEN_126F&DEV_2263
|
|
existed in Plug and Play history but was initially shown with status
|
|
Unknown in the non-PresentOnly query.
|
|
|
|
- time: "2026-09-14 before restart"
|
|
event: "PnP disk inventory"
|
|
notes: >
|
|
A 1TB PCS PCIe M.2 SSD device entry existed in Plug and Play history
|
|
but was initially shown with status Unknown in the non-PresentOnly
|
|
query. Numerous historical USB storage entries were also present,
|
|
demonstrating that this query included devices not currently attached.
|
|
|
|
- time: "2026-09-14 before restart"
|
|
event: "SATA reliability telemetry"
|
|
notes: >
|
|
Get-StorageReliabilityCounter returned data for DeviceId 0, the visible
|
|
128 GB SATA SSD: 2033 power-on hours, 40 C temperature, wear 0,
|
|
ReadErrorsTotal 0, ReadErrorsUncorrected 0, maximum read latency
|
|
4253 ms and maximum write latency 6122 ms. This telemetry did not
|
|
describe the 1 TB NVMe.
|
|
|
|
- time: "2026-09-14 restart / BIOS inspection"
|
|
event: "BIOS storage inspection"
|
|
notes: >
|
|
The BIOS menus inspected by the operator did not show a 1 TB NVMe or
|
|
SATA storage device. This observation is retained as evidence, but the
|
|
exact Clevo/Insyde BIOS menu capabilities have not been established;
|
|
absence from a BIOS menu does not by itself prove failure to enumerate
|
|
the PCIe function.
|
|
|
|
- time: "2026-09-14 16:15:38"
|
|
event: "NVMe controller arrival after reboot"
|
|
notes: >
|
|
Windows recorded the Standard NVM Express Controller LastArrivalDate
|
|
as 2026-09-14 16:15:38.
|
|
|
|
- time: "2026-09-14 ~16:15 onward"
|
|
event: "PresentOnly controller enumeration"
|
|
notes: >
|
|
Get-PnpDevice -PresentOnly positively enumerated the Standard NVM
|
|
Express Controller as present with Status OK.
|
|
|
|
- time: "2026-09-14 ~16:15 onward"
|
|
event: "PresentOnly 1 TB NVMe disk enumeration"
|
|
notes: >
|
|
Get-PnpDevice -PresentOnly -Class DiskDrive positively enumerated
|
|
1TB PCS PCIe M.2 SSD with Status OK alongside the 128 GB SATA SSD.
|
|
|
|
- time: "2026-09-14 ~16:15 onward"
|
|
event: "Get-Disk still omitted NVMe"
|
|
notes: >
|
|
Despite positive current PnP enumeration of the NVMe controller and
|
|
disk device, Get-Disk still exposed only the 128 GB SATA SSD.
|
|
|
|
- time: "2026-09-14 ~16:15 onward"
|
|
event: "NVMe controller state inspected"
|
|
notes: >
|
|
The controller reported CM_PROB_NONE, ConfigManagerErrorCode
|
|
CM_PROB_NONE, Status OK, Present True, HasProblem False and service
|
|
stornvme.
|
|
|
|
- time: "2026-09-14 ~16:15 onward"
|
|
event: "NVMe PCIe link inspected"
|
|
notes: >
|
|
Device properties reported PCI bus 2, device 0, function 0,
|
|
CurrentLinkSpeed 3, CurrentLinkWidth 4, MaxLinkSpeed 3 and
|
|
MaxLinkWidth 4. The controller was therefore actively enumerated on a
|
|
PCIe Gen3 x4 link at the time of inspection.
|
|
|
|
- time: "2026-09-14 16:23:21"
|
|
event: "New NVMe controller error"
|
|
notes: >
|
|
stornvme Event 11 reported: "The driver detected a controller error on
|
|
\Device\RaidPort2." This event occurred during the current diagnostic
|
|
session after the NVMe controller had arrived and been enumerated.
|
|
|
|
- time: "2026-09-14 after 16:23"
|
|
event: "Historical stornvme event review"
|
|
notes: >
|
|
Event-log review confirmed repeated Event 129 device resets and
|
|
Event 11 controller errors on \Device\RaidPort2 on 2026-09-04 and
|
|
repeatedly in June and March 2026. The pattern therefore predates the
|
|
September incident.
|
|
|
|
- time: "2026-09-14 after event review"
|
|
event: "Post-repair SFC verification"
|
|
notes: >
|
|
A second sfc /scannow completed with "Windows Resource Protection did
|
|
not find any integrity violations."
|
|
|
|
findings:
|
|
- title: "Fast Startup disabled for diagnosis"
|
|
severity: "info"
|
|
status: "completed"
|
|
evidence: >
|
|
powercfg /h off completed successfully.
|
|
assessment: >
|
|
Disabling hibernation disables Windows Fast Startup and removes the
|
|
previously observed Fast Startup path from subsequent shutdown and boot
|
|
tests. This is an appropriate diagnostic control and should remain in
|
|
place until the investigation is complete.
|
|
|
|
- title: "Windows component-store corruption"
|
|
severity: "medium"
|
|
status: "repaired"
|
|
evidence: >
|
|
DISM /Online /Cleanup-Image /RestoreHealth completed successfully.
|
|
assessment: >
|
|
A Windows integrity problem existed and was repaired. The evidence does
|
|
not establish whether corruption contributed to the hard freezes,
|
|
resulted from forced power-offs, or was unrelated.
|
|
|
|
- title: "Protected Windows system-file corruption"
|
|
severity: "medium"
|
|
status: "repaired"
|
|
evidence: >
|
|
The first sfc /scannow found corrupt files and repaired them. A later
|
|
sfc /scannow after restart reported no integrity violations.
|
|
assessment: >
|
|
Windows protected-file integrity is currently clean. Recurrent immediate
|
|
corruption was not observed after repair and reboot.
|
|
|
|
- title: "1 TB NVMe absent from Get-Disk / Get-PhysicalDisk"
|
|
severity: "high"
|
|
status: "confirmed"
|
|
evidence: >
|
|
Before restart, both Get-Disk and Get-PhysicalDisk exposed only the
|
|
128 GB PCS SATA SSD. After restart, Get-Disk still exposed only the
|
|
SATA SSD even though PresentOnly PnP enumeration showed the NVMe
|
|
controller and 1 TB NVMe disk as currently present.
|
|
assessment: >
|
|
Windows can enumerate the PCIe NVMe function and child disk device but
|
|
does not currently expose the 1 TB NVMe as a normal usable disk through
|
|
the storage-management layer. This strongly supports a problem in the
|
|
NVMe storage path rather than a simple stale Device Manager entry.
|
|
|
|
- title: "1 TB NVMe positively present on PCIe after reboot"
|
|
severity: "high"
|
|
status: "confirmed"
|
|
evidence: >
|
|
Get-PnpDevice -PresentOnly reported the Standard NVM Express Controller
|
|
and 1TB PCS PCIe M.2 SSD as present with Status OK. The controller
|
|
reported Present True, HasProblem False, CM_PROB_NONE and a PCIe Gen3
|
|
x4 link.
|
|
assessment: >
|
|
The controller was physically enumerated at the PCIe level during the
|
|
session. Therefore the device was not simply absent from the PCIe bus at
|
|
the moment these properties were queried. This does not demonstrate
|
|
reliable access to the NVMe media.
|
|
|
|
- title: "Current-session stornvme controller error"
|
|
severity: "high"
|
|
status: "confirmed"
|
|
evidence: >
|
|
stornvme Event 11 occurred at 2026-09-14 16:23:21 and reported a
|
|
controller error on \Device\RaidPort2.
|
|
assessment: >
|
|
This is direct evidence of an active storage-controller/path failure
|
|
during the current session. It materially raises the priority of the
|
|
1 TB NVMe path as a potential explanation for the historical freezes.
|
|
|
|
- title: "Long-running RaidPort2 reset / error pattern"
|
|
severity: "high"
|
|
status: "confirmed"
|
|
evidence: >
|
|
Historical logs contain repeated stornvme Event 129 resets and Event 11
|
|
controller errors on \Device\RaidPort2 on 2026-09-04 and repeatedly in
|
|
June and March 2026.
|
|
assessment: >
|
|
The storage-path problem is recurrent and predates the September 2026
|
|
hard-freeze investigation. This makes a one-off Windows corruption event
|
|
an insufficient explanation for the controller-error history.
|
|
|
|
- title: "NVMe physical failure not yet proven"
|
|
severity: "high"
|
|
status: "open"
|
|
evidence: >
|
|
The NVMe controller and child disk can currently enumerate on PCIe and
|
|
report PnP Status OK, while stornvme simultaneously records controller
|
|
errors and the disk remains absent from Get-Disk.
|
|
assessment: >
|
|
The evidence is compatible with a failing NVMe SSD, but does not yet
|
|
distinguish the SSD itself from the M.2 connection, motherboard slot /
|
|
PCIe path, controller firmware, system firmware interaction or power
|
|
delivery. The drive should not yet be condemned solely from Event 11.
|
|
|
|
- title: "BIOS does not list 1 TB storage device in inspected menus"
|
|
severity: "medium"
|
|
status: "observed"
|
|
evidence: >
|
|
During the 2026-09-14 BIOS inspection, no 1 TB NVMe/SATA device was
|
|
visible to the operator.
|
|
assessment: >
|
|
Retain this as an important observation. However, the available evidence
|
|
does not establish whether this specific Insyde BIOS exposes NVMe device
|
|
inventory in its UI. Windows later demonstrated active PCIe enumeration,
|
|
so absence from the visible BIOS menus must not be treated as conclusive
|
|
proof that firmware failed to enumerate the controller.
|
|
|
|
- title: "NVRAM / CMOS retention issue"
|
|
severity: "high"
|
|
status: "open"
|
|
evidence: >
|
|
The original firmware warning reported a first-boot or NVRAM-reset
|
|
condition.
|
|
assessment: >
|
|
The warning remains unexplained. A failed RTC/CMOS battery is possible
|
|
but not proven. A controlled unpowered retention test of BIOS time and
|
|
settings remains required. This issue should remain diagnostically
|
|
separate from the NVMe fault unless further evidence connects them.
|
|
|
|
- title: "TPM / Measured Boot pre-attestation failure"
|
|
severity: "medium"
|
|
status: "open"
|
|
evidence: >
|
|
TPM-WMI Event 1040 previously reported a critical pre-attestation
|
|
health-check failure and referenced a MeasuredBoot JSON diagnostic file.
|
|
assessment: >
|
|
The temporal association with the NVRAM warning makes a firmware-state
|
|
relationship plausible, but no causal relationship has been proven.
|
|
The TPM should not be cleared merely as a diagnostic experiment.
|
|
|
|
- title: "128 GB SATA SSD telemetry"
|
|
severity: "info"
|
|
status: "currently-normal"
|
|
evidence: >
|
|
The visible SATA SSD reported Healthy / OK, 40 C, wear 0,
|
|
ReadErrorsTotal 0 and ReadErrorsUncorrected 0 in the supplied reliability
|
|
counter output.
|
|
assessment: >
|
|
No direct read-error evidence was observed for the 128 GB SATA SSD in
|
|
this checkpoint. The unusually high recorded maximum latency values are
|
|
retained for completeness but are not by themselves sufficient to
|
|
diagnose failure.
|
|
|
|
sections:
|
|
- title: "Commands and results — boot / shutdown control"
|
|
content:
|
|
- type: bullets
|
|
items:
|
|
- >
|
|
powercfg /h off — completed without error; hibernation and Fast
|
|
Startup disabled.
|
|
- >
|
|
Previous full-shutdown test bypassing Fast Startup — completed
|
|
normally.
|
|
- >
|
|
Previous normal restart test — completed normally.
|
|
|
|
- title: "Commands and results — Windows integrity"
|
|
content:
|
|
- type: bullets
|
|
items:
|
|
- >
|
|
DISM /CheckHealth — returned Error 87 because the required
|
|
/Online /Cleanup-Image arguments were omitted. This result has no
|
|
diagnostic significance for Windows health.
|
|
- >
|
|
DISM /Online /Cleanup-Image /RestoreHealth — reached 100 percent
|
|
and completed successfully.
|
|
- >
|
|
First sfc /scannow — found corrupt files and successfully
|
|
repaired them.
|
|
- >
|
|
Second sfc /scannow after restart — no integrity violations found.
|
|
|
|
- title: "Commands and results — initial storage inventory"
|
|
content:
|
|
- type: bullets
|
|
items:
|
|
- >
|
|
Get-Disk — only Disk 0, 128GB PCS 2.5-inch SSD, SATA, Online,
|
|
Healthy, 128035676160 bytes.
|
|
- >
|
|
Get-PhysicalDisk — only 128GB PCS 2.5-inch SSD, SSD/SATA,
|
|
Healthy / OK, 128035676160 bytes.
|
|
- >
|
|
Get-PnpDevice -Class SCSIAdapter — historical list included a
|
|
Standard NVM Express Controller with PCI VEN_126F DEV_2263,
|
|
initially shown as Unknown without -PresentOnly.
|
|
- >
|
|
Get-PnpDevice -Class DiskDrive — historical list included
|
|
1TB PCS PCIe M.2 SSD, initially shown as Unknown without
|
|
-PresentOnly, along with many disconnected historical USB devices.
|
|
- >
|
|
Get-StorageReliabilityCounter — returned telemetry only for the
|
|
visible DeviceId 0 / 128 GB SATA SSD: 2033 power-on hours, 40 C,
|
|
wear 0, no reported read errors.
|
|
|
|
- title: "Commands and results — post-reboot NVMe enumeration"
|
|
content:
|
|
- type: bullets
|
|
items:
|
|
- >
|
|
Get-PnpDevice -PresentOnly -Class SCSIAdapter — Standard NVM
|
|
Express Controller present, Status OK.
|
|
- >
|
|
Get-PnpDevice -PresentOnly -Class DiskDrive — 1TB PCS PCIe M.2 SSD
|
|
present, Status OK; 128GB PCS 2.5-inch SSD also present.
|
|
- >
|
|
Get-Disk — still exposed only the 128 GB SATA SSD.
|
|
- >
|
|
PresentOnly PCI VEN_126F DEV_2263 query — controller Status OK,
|
|
class SCSIAdapter.
|
|
- >
|
|
Controller detailed properties — CM_PROB_NONE,
|
|
ConfigManagerErrorCode CM_PROB_NONE, Present True,
|
|
HasProblem False, Service stornvme.
|
|
- >
|
|
Controller PCI properties — bus 2, device 0, function 0;
|
|
current and maximum link speed 3; current and maximum link width 4;
|
|
AER capability present.
|
|
- >
|
|
Controller LastArrivalDate — 2026-09-14 16:15:38.
|
|
- >
|
|
Controller bus relation and child relationship both reference
|
|
SCSI\Disk&Ven_NVMe&Prod_1TB_PCS_PCIe_M.2.
|
|
|
|
- title: "Commands and results — storage event history"
|
|
content:
|
|
- type: bullets
|
|
items:
|
|
- >
|
|
2026-09-14 16:23:21 — stornvme Event 11:
|
|
controller error on \Device\RaidPort2.
|
|
- >
|
|
2026-09-04 17:22:40 — stornvme Event 11:
|
|
controller error on \Device\RaidPort2.
|
|
- >
|
|
2026-09-04 17:20:46 — stornvme Event 129:
|
|
reset to \Device\RaidPort2 issued.
|
|
- >
|
|
2026-09-04 17:12:39 — stornvme Event 129:
|
|
reset to \Device\RaidPort2 issued.
|
|
- >
|
|
2026-09-04 16:57:14 — stornvme Event 11:
|
|
controller error on \Device\RaidPort2.
|
|
- >
|
|
2026-09-04 16:55:20 — stornvme Event 129:
|
|
reset to \Device\RaidPort2 issued.
|
|
- >
|
|
2026-09-04 16:44:57 — stornvme Event 11:
|
|
controller error on \Device\RaidPort2.
|
|
- >
|
|
2026-09-04 16:43:03 — stornvme Event 129:
|
|
reset to \Device\RaidPort2 issued.
|
|
- >
|
|
2026-09-04 15:21:28 — stornvme Event 11:
|
|
controller error on \Device\RaidPort2.
|
|
- >
|
|
2026-09-04 15:19:32 — stornvme Event 129:
|
|
reset to \Device\RaidPort2 issued.
|
|
- >
|
|
Additional Event 11 / Event 129 occurrences were confirmed on
|
|
2026-06-09, 2026-06-08, 2026-03-26, 2026-03-21, 2026-03-20,
|
|
2026-03-19 and 2026-03-18.
|
|
|
|
- title: "BIOS / firmware observations"
|
|
content:
|
|
- type: bullets
|
|
items:
|
|
- >
|
|
Earlier investigation observed: "A first boot or NVRAM reset
|
|
condition has been detected."
|
|
- >
|
|
BIOS used during this investigation: Insyde 1.07.07TPCS1.
|
|
- >
|
|
Operator inspection on 2026-09-14 found no visible 1 TB NVMe/SATA
|
|
device in the BIOS menus examined.
|
|
- >
|
|
No BIOS update or firmware flash has been performed during this
|
|
diagnostic sequence.
|
|
- >
|
|
No TPM clear has been performed.
|
|
|
|
- title: "Interpretation at this checkpoint"
|
|
content:
|
|
- type: callout
|
|
title: "Current state"
|
|
kind: "warning"
|
|
text: >
|
|
Windows software integrity has been repaired and verified clean, but
|
|
the storage problem remains active. The 1 TB NVMe controller and
|
|
child disk can enumerate on PCIe while the disk remains absent from
|
|
Get-Disk, and a new Event 11 controller error was generated during
|
|
the current session. This substantially strengthens the NVMe /
|
|
M.2 / PCIe storage-path hypothesis for the hard-freeze investigation.
|
|
It still does not identify which physical component in that path is
|
|
defective.
|
|
|
|
- type: bullets
|
|
items:
|
|
- "Fast Startup is disabled and should remain disabled during diagnosis."
|
|
- "Windows component-store corruption has been repaired."
|
|
- "Windows protected system files are currently clean."
|
|
- "The 128 GB SATA SSD is the only disk exposed by Get-Disk."
|
|
- "The 1 TB NVMe controller is currently enumerated on PCIe Gen3 x4."
|
|
- "The 1 TB NVMe child disk is currently visible to PresentOnly PnP."
|
|
- "The 1 TB NVMe is nevertheless absent from Get-Disk."
|
|
- "A new stornvme Event 11 occurred during this diagnostic session."
|
|
- "RaidPort2 Event 11 / 129 faults recur over several months."
|
|
- "The 1 TB SSD itself is a primary suspect but is not yet conclusively proven defective."
|
|
- "M.2 seating, slot / motherboard path and power delivery remain plausible alternatives."
|
|
- "The NVRAM / CMOS issue remains open and should not yet be merged with the NVMe diagnosis."
|
|
- "TPM / Measured Boot evidence remains preserved and unresolved."
|
|
- "A BIOS flash is not currently justified as a first remediation step."
|
|
|
|
actions_title: "Recommended next diagnostic steps"
|
|
|
|
actions:
|
|
- title: "Back up important data"
|
|
status: "priority"
|
|
text: >
|
|
Ensure all important data is backed up before further manipulation or
|
|
testing. Recurrent NVMe controller resets/errors justify treating the
|
|
storage path as potentially unreliable.
|
|
|
|
- title: "Perform controlled full shutdown"
|
|
status: "pending"
|
|
text: >
|
|
With Fast Startup already disabled, perform a full shutdown before any
|
|
physical inspection.
|
|
commands:
|
|
- "shutdown /s /t 0"
|
|
|
|
- title: "Physically inspect and reseat the 1 TB M.2 NVMe"
|
|
status: "pending"
|
|
text: >
|
|
Disconnect AC power and, where service procedure permits, disconnect
|
|
the internal battery before handling the M.2 drive. Photograph the SSD
|
|
label and exact part number. Inspect the retaining screw, seating,
|
|
contacts and socket; remove and firmly reseat the SSD. Do not change
|
|
unrelated firmware settings during the same test.
|
|
|
|
- title: "Retest storage enumeration after reseat"
|
|
status: "pending"
|
|
text: >
|
|
After reseating, boot the machine and determine whether the 1 TB NVMe
|
|
becomes a normal disk and whether new stornvme errors appear.
|
|
commands:
|
|
- "Get-Disk"
|
|
- "Get-PhysicalDisk"
|
|
- "Get-PnpDevice -PresentOnly -Class SCSIAdapter"
|
|
- "Get-PnpDevice -PresentOnly -Class DiskDrive"
|
|
|
|
- title: "Review post-reseat stornvme events"
|
|
status: "pending"
|
|
text: >
|
|
Check the System log for fresh Event 11 or Event 129 entries immediately
|
|
after the test boot.
|
|
commands:
|
|
- "Get-WinEvent -FilterHashtable @{ LogName='System'; ProviderName='stornvme'; StartTime=(Get-Date).AddMinutes(-30) } | Format-List TimeCreated, Id, LevelDisplayName, Message"
|
|
|
|
- title: "Isolate SSD versus motherboard path if errors persist"
|
|
status: "pending"
|
|
text: >
|
|
If the NVMe remains absent from Get-Disk or Event 11 / 129 recurs after
|
|
reseating, test the SSD in another known-good compatible M.2 slot,
|
|
external NVMe enclosure or another system where practical. Conversely,
|
|
test a known-good compatible NVMe in the Clevo slot if available. The
|
|
purpose is to distinguish drive failure from slot / motherboard / power
|
|
failure before replacing parts.
|
|
|
|
- title: "Perform NVRAM / CMOS retention test"
|
|
status: "pending"
|
|
text: >
|
|
Record BIOS date/time and relevant settings, fully power down, disconnect
|
|
AC for an extended interval, then boot directly into BIOS and verify
|
|
retention. If settings or time are lost, investigate the RTC/CMOS battery,
|
|
its connection and the motherboard RTC power path.
|
|
|
|
- title: "Preserve TPM / Measured Boot evidence"
|
|
status: "pending"
|
|
text: >
|
|
Keep the referenced MeasuredBoot JSON before any TPM, Secure Boot or
|
|
firmware reset operation. Do not clear the TPM solely as a diagnostic
|
|
experiment.
|
|
commands:
|
|
- 'C:\WINDOWS\Logs\MeasuredBoot\0000000053-0000000000.json'
|
|
|
|
- title: "Defer BIOS flashing"
|
|
status: "hold"
|
|
text: >
|
|
Do not flash BIOS/EC firmware while the machine has an unresolved
|
|
intermittent storage fault unless a later, model-specific remediation
|
|
path explicitly requires it and power/storage stability has first been
|
|
established.
|
|
|
|
closing: >
|
|
At this checkpoint the Windows repair is complete and verified, while the
|
|
storage-path fault remains active and repeatable. The strongest evidence is
|
|
the coexistence of a currently enumerated PCIe Gen3 x4 NVMe controller,
|
|
failure of the 1 TB NVMe to appear in Get-Disk, and a fresh stornvme Event 11
|
|
on \Device\RaidPort2 during the 2026-09-14 session, backed by months of
|
|
historical Event 11 and Event 129 activity. The immediate priority is
|
|
preservation of data followed by physical M.2 inspection/reseat and controlled
|
|
device-versus-slot isolation. The firmware NVRAM/CMOS and TPM/Measured Boot
|
|
findings remain unresolved parallel tracks and should not yet be assumed to
|
|
share the same root cause. |