id: "BEF-2026-09-15-CLEVO-DIAG-001"
|
||||
|
||||
organization: "Beffroi"
|
||||
|
||||
title: "System Stability Investigation — Diagnostic Test Record"
|
||||
subtitle: "Chronic NVMe controller errors, PCIe device instability and hard-freeze correlation — internal technical notes"
|
||||
|
||||
report_type: technical
|
||||
theme: default
|
||||
|
||||
status: "open"
|
||||
severity: "high"
|
||||
|
||||
metadata:
|
||||
Date: "2026-09-15"
|
||||
Device: "DESKTOP-SAU019H"
|
||||
Manufacturer: "PC Specialist / Clevo"
|
||||
Platform: "NH5x_NH7x_HHx_HJx_HKx"
|
||||
Motherboard: "CLEVO NHxxHJHK"
|
||||
BIOS: "Insyde 1.07.07TPCS1 — 2021-09-16"
|
||||
OS: "Windows 11 Pro — 10.0.26200 / build 26200"
|
||||
CPU: "Intel Core i7-11800H"
|
||||
Memory: "16 GB Corsair — single module"
|
||||
Graphics: "Intel UHD Graphics + NVIDIA GeForce GTX 1650"
|
||||
SystemDrive: "128GB PCS 2.5\" SATA SSD — serial U9DI16295T"
|
||||
SecondaryStorage: "1TB PCS PCIe M.2 SSD — NVMe — intermittently unusable from Windows storage stack"
|
||||
NVMeController: "Silicon Motion PCI VEN_126F DEV_2263 family — Microsoft stornvme"
|
||||
Wireless: "Intel(R) Wi-Fi 6 AX200 160MHz"
|
||||
Author: "Maximilien Rigaut"
|
||||
Purpose: "Internal technical diagnostic notes; preserve evidence and working hypotheses pending hardware isolation"
|
||||
|
||||
summary: >
|
||||
Investigation of DESKTOP-SAU019H has progressed from a general Windows
|
||||
stability investigation to a substantially more focused hardware/platform
|
||||
investigation. Windows component-store and protected system-file corruption
|
||||
identified during the investigation were successfully repaired. A subsequent
|
||||
SFC validation after reboot reported no integrity violations. Fast Startup
|
||||
was also disabled to remove the previously demonstrated hybrid-shutdown
|
||||
failure path from further testing.
|
||||
|
||||
Despite establishing this cleaner Windows baseline, the underlying instability
|
||||
persists. The 1 TB PCS PCIe M.2 SSD and its NVMe controller continue to exhibit
|
||||
repeated stornvme Event 129 device resets and Event 11 controller errors on
|
||||
\Device\RaidPort2. These errors are not confined to the September incident:
|
||||
review of historical event data establishes recurrence across March, June,
|
||||
September 4, September 14 and September 15 2026.
|
||||
|
||||
Windows currently demonstrates an important split in device state. The
|
||||
Standard NVM Express Controller and the child "1TB PCS PCIe M.2 SSD" can be
|
||||
enumerated as physically present by Plug and Play, with the controller
|
||||
reporting Status OK, CM_PROB_NONE and an active PCIe Gen3 x4 link. However,
|
||||
Get-Disk and Get-PhysicalDisk have failed to expose the 1 TB NVMe as a normal
|
||||
usable storage device while the 128 GB SATA SSD remains available.
|
||||
|
||||
The 2026-09-15 evidence adds a second major dimension to the investigation.
|
||||
During the hard-freeze episode reported at approximately 09:18-09:20, the
|
||||
Intel Wi-Fi 6 AX200 also entered a severe failure sequence consisting of an
|
||||
internal adapter failure, TX/CMD timeout, reports that the adapter was not
|
||||
functioning correctly, invalid driver-returned values and miniport reset
|
||||
watchdog events. A stornvme Event 11 against \Device\RaidPort2 occurred
|
||||
during the same failure cluster.
|
||||
|
||||
Historical review identifies comparable coupled NVMe / AX200 episodes on at
|
||||
least 2026-03-19 and 2026-06-08. This recurrence materially increases concern
|
||||
that the observed instability may extend beyond an isolated Windows problem
|
||||
or a single storage-device failure. A failing NVMe SSD remains a credible
|
||||
explanation for the persistent RaidPort2 failures, but a shared platform-level
|
||||
fault involving the M.2/PCIe path, motherboard/chipset, platform power
|
||||
delivery, firmware or another common dependency must now be considered a
|
||||
leading diagnostic branch.
|
||||
|
||||
No single hardware component has yet been conclusively proven defective.
|
||||
Hardware substitution and isolation testing are required before authorizing
|
||||
replacement of the SSD, motherboard or other components.
|
||||
|
||||
timeline:
|
||||
- time: "2026-03-17 through 2026-03-26"
|
||||
event: "Historical NVMe fault activity"
|
||||
notes: >
|
||||
Historical System log review shows repeated stornvme Event 129 resets
|
||||
and/or Event 11 controller errors against \Device\RaidPort2 across
|
||||
multiple days in March. The storage fault pattern therefore predates the
|
||||
September investigation by approximately six months.
|
||||
|
||||
- time: "2026-03-19 ~08:17-08:20"
|
||||
event: "Historical coupled NVMe and AX200 failure episode"
|
||||
notes: >
|
||||
A RaidPort2 reset was recorded at approximately 08:17:31. Roughly
|
||||
one and a half minutes later the Intel Wi-Fi 6 AX200 entered a failure
|
||||
sequence including Event 5005 internal failure, Event 5007 TX/CMD timeout,
|
||||
Event 5002 adapter-not-functioning reports and Event 5032 miniport reset
|
||||
watchdog activity. stornvme subsequently recorded Event 11 against
|
||||
\Device\RaidPort2 at approximately 08:19:26. This is the earliest
|
||||
currently identified example of storage and wireless failures clustering
|
||||
in the same short time interval.
|
||||
|
||||
- time: "2026-06-08 ~12:10-12:16"
|
||||
event: "Second historical coupled NVMe and AX200 failure episode"
|
||||
notes: >
|
||||
RaidPort2 reset events occurred at approximately 12:10:31 and 12:12:09.
|
||||
At approximately 12:13:11 the AX200 experienced another TX/CMD timeout
|
||||
and associated adapter/reset-watchdog failures. Another NVMe reset was
|
||||
issued at approximately 12:14:01 followed by stornvme Event 11 at
|
||||
approximately 12:14:04. Additional storage and wireless fault activity
|
||||
continued within the same incident window. The similarity to the March
|
||||
and September sequences materially strengthens the correlation.
|
||||
|
||||
- time: "2026-06-09"
|
||||
event: "Additional historical RaidPort2 errors"
|
||||
notes: >
|
||||
Additional stornvme Event 129 / Event 11 activity was identified without
|
||||
requiring a simultaneous AX200 failure. This demonstrates that storage
|
||||
instability can occur independently of the wireless failure sequence.
|
||||
|
||||
- time: "2026-09-04 before ~17:23"
|
||||
event: "Hard-freeze incident"
|
||||
notes: >
|
||||
System experienced a hard freeze before approximately 17:23. Exact freeze
|
||||
onset was not timestamped.
|
||||
|
||||
- time: "2026-09-04 ~17:25"
|
||||
event: "Second hard-freeze / hang"
|
||||
notes: >
|
||||
A second hang was observed at approximately 17:25. Normal shutdown could
|
||||
not subsequently be completed and a forced power-off was required.
|
||||
|
||||
- time: "2026-09-04"
|
||||
event: "Firmware/NVRAM warning observed"
|
||||
notes: >
|
||||
Firmware displayed "A first boot or NVRAM reset condition has been
|
||||
detected." This remains an independent unresolved firmware-state finding.
|
||||
The warning alone does not establish failure of the RTC/CMOS battery.
|
||||
|
||||
- time: "2026-09-04"
|
||||
event: "Fast Startup failure identified"
|
||||
notes: >
|
||||
Kernel-Boot Event 29 recorded a Fast Startup failure with status
|
||||
0xC000007B. Restart and a full shutdown bypassing Fast Startup subsequently
|
||||
completed successfully.
|
||||
|
||||
- time: "2026-09-04"
|
||||
event: "RaidPort2 errors identified"
|
||||
notes: >
|
||||
System logs showed repeated stornvme Event 129 resets and Event 11
|
||||
controller errors against \Device\RaidPort2 around the incident period.
|
||||
At this stage the responsible physical storage device had not yet been
|
||||
conclusively isolated.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Fast Startup disabled for controlled diagnosis"
|
||||
notes: >
|
||||
powercfg /h off completed successfully. This disables hibernation and
|
||||
Windows Fast Startup, removing the previously abnormal hybrid-shutdown
|
||||
path as a variable during subsequent testing.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Windows component-store repair"
|
||||
notes: >
|
||||
DISM /Online /Cleanup-Image /RestoreHealth completed at 100 percent with
|
||||
"The restore operation completed successfully" and "The operation
|
||||
completed successfully."
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Windows protected-file repair"
|
||||
notes: >
|
||||
sfc /scannow found corrupt Windows files and successfully repaired them.
|
||||
|
||||
- time: "2026-09-14 after reboot"
|
||||
event: "Post-repair Windows integrity verification"
|
||||
notes: >
|
||||
A subsequent sfc /scannow reported "Windows Resource Protection did not
|
||||
find any integrity violations." The Windows integrity repair therefore
|
||||
remained clean across the reboot.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Storage inventory discrepancy identified"
|
||||
notes: >
|
||||
Get-Disk and Get-PhysicalDisk exposed only the 128 GB PCS 2.5-inch SATA
|
||||
SSD. The expected 1 TB PCS PCIe M.2 SSD was not exposed as a normal disk.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "NVMe controller positively enumerated"
|
||||
notes: >
|
||||
Get-PnpDevice -PresentOnly enumerated a Standard NVM Express Controller
|
||||
using PCI identifier VEN_126F&DEV_2263. The controller reported Status OK
|
||||
and was bound to the Microsoft stornvme driver.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "1 TB NVMe child device positively enumerated"
|
||||
notes: >
|
||||
Get-PnpDevice -PresentOnly -Class DiskDrive enumerated
|
||||
"1TB PCS PCIe M.2 SSD" with Status OK. The 128 GB SATA SSD was also
|
||||
present.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "NVMe PnP state inspected"
|
||||
notes: >
|
||||
Detailed controller properties reported Present True, HasProblem False,
|
||||
CM_PROB_NONE and ConfigManagerErrorCode CM_PROB_NONE. Windows therefore
|
||||
did not consider the PCI device absent or in a conventional PnP error
|
||||
state.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "NVMe PCIe link inspected"
|
||||
notes: >
|
||||
Controller properties identified PCI bus 2, device 0, function 0 with
|
||||
current link speed 3 and link width 4, matching maximum link speed 3 and
|
||||
width 4. The NVMe controller was therefore actively linked at PCIe Gen3
|
||||
x4 during inspection.
|
||||
|
||||
- time: "2026-09-14 16:23:21"
|
||||
event: "Fresh stornvme controller error"
|
||||
notes: >
|
||||
stornvme Event 11 reported "The driver detected a controller error on
|
||||
\Device\RaidPort2." This occurred after Windows repair and while the NVMe
|
||||
controller was currently enumerated.
|
||||
|
||||
- time: "2026-09-15 08:54:49"
|
||||
event: "Current diagnostic boot"
|
||||
notes: >
|
||||
Intel AX200 initialization events were recorded during the current boot.
|
||||
The adapter initially entered service normally.
|
||||
|
||||
- time: "2026-09-15 08:55:20"
|
||||
event: "RaidPort2 reset"
|
||||
notes: >
|
||||
stornvme Event 129 reported "Reset to device, \Device\RaidPort2, was
|
||||
issued."
|
||||
|
||||
- time: "2026-09-15 08:56:23"
|
||||
event: "Second RaidPort2 reset"
|
||||
notes: >
|
||||
A second stornvme Event 129 reset was issued against \Device\RaidPort2
|
||||
approximately one minute after the first.
|
||||
|
||||
- time: "2026-09-15 08:58:17"
|
||||
event: "RaidPort2 controller error"
|
||||
notes: >
|
||||
stornvme Event 11 reported a controller error against
|
||||
\Device\RaidPort2. The storage path was therefore already producing
|
||||
errors well before the later hard freeze.
|
||||
|
||||
- time: "2026-09-15 ~09:18-09:20"
|
||||
event: "Hard system freeze"
|
||||
notes: >
|
||||
User observed another hard system freeze. The event-log cluster immediately
|
||||
surrounding this incident contains simultaneous severe AX200 and NVMe
|
||||
storage failures.
|
||||
|
||||
- time: "2026-09-15 09:19:52"
|
||||
event: "AX200 severe failure begins"
|
||||
notes: >
|
||||
Netwtw10 Event 5005 reported that Intel(R) Wi-Fi 6 AX200 160MHz
|
||||
encountered an internal error and failed. Event 5007 reported a TX/CMD
|
||||
timeout with a hung TfdQueue.
|
||||
|
||||
- time: "2026-09-15 09:19:53-09:19:57"
|
||||
event: "AX200 failure and recovery cascade"
|
||||
notes: >
|
||||
The AX200 generated Event 5002 reports stating that the adapter was not
|
||||
functioning properly, followed by a large burst of Event 5010 messages
|
||||
reporting invalid values returned to the driver. Event 5032 subsequently
|
||||
recorded Driver Miniport reset watchdog failures. This represents a
|
||||
substantive adapter/driver/device communication failure rather than a
|
||||
routine Wi-Fi disconnect.
|
||||
|
||||
- time: "2026-09-15 09:19:56"
|
||||
event: "NVMe controller error during AX200 failure cluster"
|
||||
notes: >
|
||||
stornvme Event 11 reported "The driver detected a controller error on
|
||||
\Device\RaidPort2" during the same second as the AX200 Event 5010 storm.
|
||||
The temporal coincidence is diagnostically significant, particularly
|
||||
because comparable clustering is present in March and June historical
|
||||
logs.
|
||||
|
||||
findings:
|
||||
- title: "Chronic RaidPort2 / NVMe storage-path instability"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
Repeated stornvme Event 129 device resets and Event 11 controller errors
|
||||
against \Device\RaidPort2 occur across multiple months, including March,
|
||||
June, September 4, September 14 and September 15 2026. Fresh resets and
|
||||
controller errors continue after Windows component-store and system-file
|
||||
repair.
|
||||
assessment: >
|
||||
The recurrence establishes a persistent low-level storage-path problem.
|
||||
This is no longer reasonably explained as a single transient Windows
|
||||
incident. The evidence demonstrates failure somewhere in the NVMe device /
|
||||
M.2 slot / PCIe path / associated platform stack, but does not by itself
|
||||
identify which physical component is defective.
|
||||
|
||||
- title: "1 TB NVMe is enumerated but not exposed as a usable disk"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
PresentOnly PnP enumeration identifies both the Standard NVM Express
|
||||
Controller and its 1TB PCS PCIe M.2 SSD child device. The controller
|
||||
reports Status OK, CM_PROB_NONE and an active PCIe Gen3 x4 link. Despite
|
||||
this, Get-Disk and Get-PhysicalDisk expose only the 128 GB SATA SSD.
|
||||
assessment: >
|
||||
PCIe enumeration alone is therefore not evidence that the NVMe storage
|
||||
device is operational. The controller can establish a PCIe/PnP presence
|
||||
while the storage stack is unable to expose the underlying media as a
|
||||
normal disk. This strongly implicates the NVMe storage path.
|
||||
|
||||
- title: "Severe Intel AX200 failure correlated with September 15 freeze"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
During the September 15 hard-freeze window, the AX200 generated Event
|
||||
5005 internal failures, Event 5007 TX/CMD timeout, Event 5002
|
||||
adapter-not-functioning reports, a very large Event 5010 invalid-value
|
||||
burst and Event 5032 miniport reset watchdog failures.
|
||||
assessment: >
|
||||
The wireless subsystem experienced a genuine low-level failure during
|
||||
the freeze interval. This does not prove that the AX200 caused the system
|
||||
freeze. Its diagnostic importance is primarily the temporal correlation
|
||||
with the concurrent NVMe controller failure.
|
||||
|
||||
- title: "Repeated cross-device NVMe / AX200 failure correlation"
|
||||
severity: "high"
|
||||
status: "confirmed-correlation"
|
||||
evidence: >
|
||||
Comparable short-window clustering of RaidPort2 reset/controller errors
|
||||
and severe AX200 failures has now been identified on at least three
|
||||
distinct dates: 2026-03-19, 2026-06-08 and 2026-09-15.
|
||||
assessment: >
|
||||
Repetition on three separated dates makes accidental one-time temporal
|
||||
coincidence substantially less plausible. The evidence establishes a
|
||||
repeatable correlation, not causation. A common platform dependency,
|
||||
platform power issue, PCIe/chipset problem, firmware interaction or a
|
||||
severe fault in one device disrupting the wider platform are credible
|
||||
explanations requiring hardware isolation.
|
||||
|
||||
- title: "RaidPort2 failures also occur without visible AX200 failure"
|
||||
severity: "medium"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
RaidPort2 resets/controller errors are present on additional dates where
|
||||
the reviewed event window does not show a corresponding severe AX200
|
||||
failure cluster.
|
||||
assessment: >
|
||||
The NVMe/storage problem therefore has an independent persistent
|
||||
manifestation. The AX200 correlation appears to accompany some severe
|
||||
incidents rather than every storage-path fault. This prevents treating
|
||||
the AX200 as a necessary cause of every RaidPort2 event.
|
||||
|
||||
- title: "Windows component-store corruption"
|
||||
severity: "medium"
|
||||
status: "repaired"
|
||||
evidence: >
|
||||
DISM /Online /Cleanup-Image /RestoreHealth completed successfully.
|
||||
assessment: >
|
||||
Windows corruption was genuine but has been repaired. Continued
|
||||
stornvme failures after repair substantially weaken Windows component-store
|
||||
corruption as the primary explanation for the continuing hardware
|
||||
symptoms.
|
||||
|
||||
- title: "Protected Windows system-file corruption"
|
||||
severity: "medium"
|
||||
status: "repaired-and-verified"
|
||||
evidence: >
|
||||
sfc /scannow initially found and repaired corrupt files. A subsequent SFC
|
||||
run after reboot reported no integrity violations.
|
||||
assessment: >
|
||||
Windows protected-file integrity is currently clean. Earlier corruption
|
||||
may have resulted from forced power-offs or storage instability, may have
|
||||
contributed to instability, or may have been unrelated. Direction of
|
||||
causality is not established.
|
||||
|
||||
- title: "Fast Startup failure"
|
||||
severity: "medium"
|
||||
status: "mitigated-for-diagnosis"
|
||||
evidence: >
|
||||
Earlier Kernel-Boot Event 29 identified a Fast Startup failure with status
|
||||
0xC000007B. powercfg /h off was subsequently used successfully.
|
||||
assessment: >
|
||||
Fast Startup was a real abnormality but is now removed from the diagnostic
|
||||
path. The persistence of storage errors and another hard freeze with
|
||||
hibernation/Fast Startup disabled demonstrates that Fast Startup cannot
|
||||
explain the entire incident.
|
||||
|
||||
- title: "Firmware / NVRAM reset warning"
|
||||
severity: "medium"
|
||||
status: "open"
|
||||
evidence: >
|
||||
Firmware previously displayed "A first boot or NVRAM reset condition has
|
||||
been detected."
|
||||
assessment: >
|
||||
This remains unresolved. The warning is insufficient by itself to diagnose
|
||||
a failed RTC/CMOS battery. A retention test is still required. Given the
|
||||
emerging possibility of a platform-level fault, the firmware finding
|
||||
should remain visible rather than being dismissed as unrelated.
|
||||
|
||||
- title: "BIOS storage visibility"
|
||||
severity: "medium"
|
||||
status: "inconclusive"
|
||||
evidence: >
|
||||
During manual BIOS inspection, the expected 1 TB NVMe was not visibly
|
||||
listed in the inspected storage menus.
|
||||
assessment: >
|
||||
This observation is useful but not conclusive because the exact Clevo /
|
||||
Insyde firmware interface may not expose NVMe inventory in the inspected
|
||||
menu. Windows subsequently demonstrated physical PCIe/PnP enumeration of
|
||||
the NVMe controller and child disk. BIOS-menu absence must therefore not
|
||||
be treated as proof that the PCIe device failed firmware enumeration.
|
||||
|
||||
- title: "128 GB SATA SSD remains normally exposed"
|
||||
severity: "info"
|
||||
status: "currently-operational"
|
||||
evidence: >
|
||||
Get-Disk and Get-PhysicalDisk consistently expose the 128GB PCS 2.5-inch
|
||||
SATA SSD as Online / Healthy / OK. Reliability telemetry reported
|
||||
approximately 2033 power-on hours, 40 C temperature, wear 0 and no
|
||||
reported total or uncorrected read errors.
|
||||
assessment: >
|
||||
Available telemetry does not presently implicate the SATA system disk in
|
||||
the same manner as the missing NVMe device. These counters must not be
|
||||
mistakenly attributed to the 1 TB NVMe.
|
||||
|
||||
diagnostics:
|
||||
confidence_scale:
|
||||
type: "investigator-estimate"
|
||||
range: "0-100"
|
||||
interpretation: >
|
||||
Confidence values below are engineering diagnostic estimates derived from
|
||||
the currently available evidence. They are not statistical probabilities,
|
||||
failure-rate calculations or manufacturer test results. They express the
|
||||
relative strength of each working hypothesis and should be revised after
|
||||
hardware isolation testing.
|
||||
|
||||
hypotheses:
|
||||
- id: "D1"
|
||||
diagnosis: "Persistent fault in the 1 TB NVMe / M.2 / PCIe storage path"
|
||||
confidence: "very-high"
|
||||
confidence_percent: 95
|
||||
scope: "fault-domain"
|
||||
status: "strongly-supported"
|
||||
evidence_for:
|
||||
- "Repeated stornvme Event 129 resets across multiple months."
|
||||
- "Repeated stornvme Event 11 controller errors across multiple months."
|
||||
- "Fresh Event 129 and Event 11 activity after Windows repair."
|
||||
- "1 TB NVMe PnP device is present while Get-Disk does not expose usable media."
|
||||
- "NVMe controller can establish PCIe Gen3 x4 while storage functionality remains unavailable."
|
||||
evidence_against:
|
||||
- "PnP controller reports Status OK and CM_PROB_NONE."
|
||||
- "No hardware substitution test has yet identified the exact failed element."
|
||||
interpretation: >
|
||||
Confidence is high that the fault domain includes the 1 TB NVMe storage
|
||||
path. This does not mean there is 95 percent confidence that the SSD
|
||||
module itself is defective; SSD, connector, slot, motherboard path,
|
||||
power and firmware remain inside this fault domain.
|
||||
tests_to_confirm:
|
||||
- "Reseat the 1 TB NVMe and repeat enumeration/event checks."
|
||||
- "Test the suspect NVMe in a known-good compatible system or enclosure."
|
||||
- "Test a known-good compatible NVMe in the Clevo M.2 slot."
|
||||
|
||||
- id: "D2"
|
||||
diagnosis: "Failure of the 1 TB NVMe SSD module itself"
|
||||
confidence: "moderate-high"
|
||||
confidence_percent: 70
|
||||
scope: "component"
|
||||
status: "probable-but-unconfirmed"
|
||||
evidence_for:
|
||||
- "Persistent controller resets/errors associated with its storage path."
|
||||
- "Device can enumerate while usable disk media is unavailable."
|
||||
- "Symptoms recur over several months."
|
||||
evidence_against:
|
||||
- "The controller establishes a normal-width PCIe Gen3 x4 link."
|
||||
- "No direct SMART/health telemetry from the missing NVMe has been obtained."
|
||||
- "A defective M.2 slot, motherboard path or power source can produce similar symptoms."
|
||||
- "Concurrent AX200 failures raise concern about a wider platform issue."
|
||||
interpretation: >
|
||||
The SSD remains a strong individual-component suspect but should not yet
|
||||
be condemned solely from stornvme Event 11/129. A/B substitution is
|
||||
required before assigning the fault specifically to the SSD.
|
||||
tests_to_confirm:
|
||||
- "Test suspect SSD externally or in another known-good PCIe/NVMe host."
|
||||
- "Install a known-good NVMe in the Clevo slot and monitor Event 11/129."
|
||||
|
||||
- id: "D3"
|
||||
diagnosis: "Motherboard / chipset / shared PCIe platform instability"
|
||||
confidence: "moderate-high"
|
||||
confidence_percent: 75
|
||||
scope: "platform"
|
||||
status: "leading-alternative"
|
||||
evidence_for:
|
||||
- "At least three dates show temporally coupled NVMe and AX200 severe failures."
|
||||
- "September 15 includes simultaneous NVMe Event 11 and AX200 failure storm during a hard freeze."
|
||||
- "March and June historical logs show similar cross-device clustering."
|
||||
- "Firmware/NVRAM anomaly exists as an additional unresolved platform-level observation."
|
||||
evidence_against:
|
||||
- "RaidPort2 failures also occur without a severe AX200 failure."
|
||||
- "No WHEA evidence currently proves PCIe root-port or chipset failure."
|
||||
- "A severely malfunctioning endpoint device can potentially destabilize software or shared platform resources without the motherboard being defective."
|
||||
- "No known-good-device substitution test has yet reproduced the failure."
|
||||
interpretation: >
|
||||
Cross-device recurrence materially raises the motherboard/platform branch
|
||||
above a speculative possibility. It is now a leading alternative to an
|
||||
isolated SSD failure, but direct evidence identifying a motherboard
|
||||
component is still absent.
|
||||
tests_to_confirm:
|
||||
- "Known-good NVMe in Clevo slot."
|
||||
- "Suspect NVMe in known-good host."
|
||||
- "If possible, operate Clevo temporarily without suspect NVMe and monitor stability."
|
||||
- "Review PCIe root-port, WHEA and ACPI/platform events during any future incident."
|
||||
- "Correlate AX200 and NVMe physical PCIe topology where possible."
|
||||
|
||||
- id: "D4"
|
||||
diagnosis: "Shared platform power-delivery instability"
|
||||
confidence: "moderate"
|
||||
confidence_percent: 60
|
||||
scope: "platform"
|
||||
status: "plausible"
|
||||
evidence_for:
|
||||
- "Multiple PCIe-connected devices have demonstrated severe failures in the same short windows."
|
||||
- "Hard freezes are compatible with severe platform-level power or bus disruption."
|
||||
- "Firmware/NVRAM anomaly provides an additional reason to retain power-state/platform hypotheses."
|
||||
evidence_against:
|
||||
- "No voltage measurement or rail telemetry is available."
|
||||
- "No direct power-controller fault has been logged."
|
||||
- "The storage fault can occur without simultaneous AX200 failure."
|
||||
interpretation: >
|
||||
Power delivery is a credible mechanism for correlated endpoint failures
|
||||
but is presently inferred rather than directly measured.
|
||||
tests_to_confirm:
|
||||
- "Repeat testing with known-good AC adapter if available and electrically compatible."
|
||||
- "Inspect motherboard and M.2 area for physical damage or thermal evidence."
|
||||
- "Compare behavior with suspect NVMe removed."
|
||||
- "Escalate to board-level diagnosis if substitution testing clears the SSD."
|
||||
|
||||
- id: "D5"
|
||||
diagnosis: "Firmware / BIOS / EC interaction affecting PCIe or power state"
|
||||
confidence: "moderate"
|
||||
confidence_percent: 50
|
||||
scope: "platform-firmware"
|
||||
status: "plausible-unconfirmed"
|
||||
evidence_for:
|
||||
- "Firmware previously reported a first-boot / NVRAM-reset condition."
|
||||
- "Failures involve devices whose state is affected by platform firmware and power management."
|
||||
- "System firmware dates from 2021 while current Windows and drivers are substantially newer."
|
||||
evidence_against:
|
||||
- "No firmware-specific error directly explains RaidPort2 failures."
|
||||
- "No BIOS/EC update comparison has been performed."
|
||||
- "No evidence currently proves that the NVRAM warning and PCIe failures share a cause."
|
||||
interpretation: >
|
||||
Firmware remains relevant but should not currently outrank the directly
|
||||
evidenced NVMe fault domain. Firmware update should not be used as the
|
||||
first uncontrolled intervention because doing so would alter the
|
||||
diagnostic baseline.
|
||||
tests_to_confirm:
|
||||
- "Perform NVRAM/RTC retention test."
|
||||
- "Document current BIOS configuration and exact firmware availability."
|
||||
- "Consider firmware update only after evidence preservation, hardware isolation and recovery preparation."
|
||||
|
||||
- id: "D6"
|
||||
diagnosis: "Intel AX200 is the primary root cause of the system freezes"
|
||||
confidence: "low-moderate"
|
||||
confidence_percent: 30
|
||||
scope: "component"
|
||||
status: "possible-but-not-leading"
|
||||
evidence_for:
|
||||
- "AX200 enters severe TX/CMD timeout and reset-watchdog failure during the September 15 freeze."
|
||||
- "Comparable AX200 failure clusters exist in March and June."
|
||||
evidence_against:
|
||||
- "Chronic RaidPort2 failures occur independently on many dates."
|
||||
- "Storage errors pre-exist some AX200 failure clusters."
|
||||
- "A concurrent failure does not establish that AX200 initiated the incident."
|
||||
- "The missing/unusable 1 TB NVMe is independently abnormal."
|
||||
interpretation: >
|
||||
The AX200 is demonstrably failing during some incidents, but current
|
||||
evidence more strongly supports treating it as either another victim of
|
||||
a shared platform fault or a secondary contributor rather than the sole
|
||||
root cause.
|
||||
|
||||
- id: "D7"
|
||||
diagnosis: "Windows corruption / Fast Startup as primary remaining root cause"
|
||||
confidence: "low"
|
||||
confidence_percent: 10
|
||||
scope: "software"
|
||||
status: "substantially-deprioritized"
|
||||
evidence_for:
|
||||
- "Windows component-store and protected-file corruption were previously confirmed."
|
||||
- "Fast Startup previously failed."
|
||||
evidence_against:
|
||||
- "DISM repair completed successfully."
|
||||
- "SFC repair completed successfully."
|
||||
- "Post-reboot SFC reported no integrity violations."
|
||||
- "Fast Startup was disabled."
|
||||
- "Fresh RaidPort2 errors occurred after repair."
|
||||
- "Another hard freeze occurred after establishing the cleaner software baseline."
|
||||
- "Storage failure history spans multiple months."
|
||||
interpretation: >
|
||||
Windows problems were real and warranted repair, but they no longer
|
||||
provide a satisfactory primary explanation for the persistent incident.
|
||||
They may instead be consequences or secondary effects of storage errors
|
||||
and forced shutdowns.
|
||||
|
||||
- id: "D8"
|
||||
diagnosis: "RTC/CMOS battery or NVRAM-retention fault"
|
||||
confidence: "low-moderate"
|
||||
confidence_percent: 35
|
||||
scope: "firmware-retention"
|
||||
status: "open"
|
||||
evidence_for:
|
||||
- "Firmware displayed a first-boot / NVRAM-reset warning."
|
||||
evidence_against:
|
||||
- "A single NVRAM warning does not establish RTC battery failure."
|
||||
- "No controlled retention test has yet demonstrated loss of clock or settings."
|
||||
- "No direct link between RTC retention and RaidPort2/AX200 failures is established."
|
||||
interpretation: >
|
||||
This remains a separate open diagnostic branch. It may eventually
|
||||
contribute to a broader motherboard diagnosis, but the current evidence
|
||||
does not justify combining the two findings.
|
||||
tests_to_confirm:
|
||||
- "Record BIOS clock and settings."
|
||||
- "Perform complete shutdown and remove external power for a controlled interval."
|
||||
- "Re-enter BIOS directly and verify clock/settings retention."
|
||||
- "Record whether the NVRAM warning recurs."
|
||||
|
||||
current_leading_assessment:
|
||||
confidence: "high"
|
||||
statement: >
|
||||
A persistent hardware-level or platform-level fault is now more likely
|
||||
than a purely Windows/software root cause. The strongest directly evidenced
|
||||
fault domain is the 1 TB NVMe / M.2 / PCIe storage path. However, repeated
|
||||
temporal correlation between severe NVMe and AX200 failures makes an
|
||||
upstream motherboard/chipset/power/firmware problem sufficiently plausible
|
||||
that the SSD should not be replaced as a conclusively diagnosed component
|
||||
without A/B hardware testing.
|
||||
|
||||
not_yet_supported:
|
||||
- "The 1 TB SSD is definitively defective."
|
||||
- "The Clevo motherboard is definitively defective."
|
||||
- "The Intel AX200 caused the hard freezes."
|
||||
- "The CMOS/RTC battery caused the NVRAM warning."
|
||||
- "The NVRAM warning and NVMe failures have a common cause."
|
||||
- "A BIOS update will resolve the problem."
|
||||
- "Windows corruption caused the original freezes."
|
||||
- "The SATA SSD is responsible for the RaidPort2 events."
|
||||
|
||||
sections:
|
||||
- title: "Commands and results — Windows baseline"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- >
|
||||
powercfg /h off — completed successfully; hibernation and Fast
|
||||
Startup disabled.
|
||||
- >
|
||||
DISM /Online /Cleanup-Image /RestoreHealth — completed successfully.
|
||||
- >
|
||||
sfc /scannow — corrupt files found and repaired.
|
||||
- >
|
||||
Post-reboot sfc /scannow — no integrity violations detected.
|
||||
- >
|
||||
Windows repair is therefore retained as completed remediation, not
|
||||
as proof of root cause.
|
||||
|
||||
- title: "Commands and results — storage enumeration"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- >
|
||||
Get-Disk — only the 128GB PCS 2.5-inch SATA SSD exposed as a normal
|
||||
disk during the affected state.
|
||||
- >
|
||||
Get-PhysicalDisk — only the 128 GB SATA device exposed.
|
||||
- >
|
||||
Get-PnpDevice -PresentOnly -Class SCSIAdapter — Standard NVM Express
|
||||
Controller present and Status OK.
|
||||
- >
|
||||
Get-PnpDevice -PresentOnly -Class DiskDrive — both 1TB PCS PCIe M.2
|
||||
SSD and 128GB PCS 2.5-inch SSD enumerated with Status OK.
|
||||
- >
|
||||
NVMe controller properties — Present True, HasProblem False,
|
||||
CM_PROB_NONE, Microsoft stornvme.
|
||||
- >
|
||||
PCIe properties — active Gen3 x4 link, matching the controller's
|
||||
reported maximum Gen3 x4 capability.
|
||||
- >
|
||||
The discrepancy between PnP presence and Get-Disk usability is a
|
||||
central diagnostic finding.
|
||||
|
||||
- title: "Commands and results — storage event history"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- >
|
||||
stornvme Event 129 repeatedly reports resets to
|
||||
\Device\RaidPort2.
|
||||
- >
|
||||
stornvme Event 11 repeatedly reports controller errors on
|
||||
\Device\RaidPort2.
|
||||
- >
|
||||
Events recur across March, June and September 2026.
|
||||
- >
|
||||
September 14 produced a fresh Event 11 after Windows repair.
|
||||
- >
|
||||
September 15 produced Event 129 at 08:55:20 and 08:56:23,
|
||||
Event 11 at 08:58:17, and another Event 11 at 09:19:56 during
|
||||
the hard-freeze/AX200 failure window.
|
||||
|
||||
- title: "Commands and results — wireless correlation"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- >
|
||||
September 15 09:19:52 — AX200 Event 5005 internal failure and
|
||||
Event 5007 TX/CMD timeout.
|
||||
- >
|
||||
September 15 09:19:53 onward — Event 5002 reports adapter not
|
||||
functioning correctly.
|
||||
- >
|
||||
September 15 09:19:56 — large Event 5010 invalid-value burst.
|
||||
- >
|
||||
September 15 09:19:56 — stornvme Event 11 occurs during the same
|
||||
second as the AX200 Event 5010 storm.
|
||||
- >
|
||||
September 15 09:19:57 — AX200 Event 5032 Driver Miniport reset
|
||||
watchdog failures.
|
||||
- >
|
||||
Comparable short-window NVMe / AX200 failure clustering was found
|
||||
on March 19 and June 8.
|
||||
|
||||
- title: "Interpretation at this checkpoint"
|
||||
content:
|
||||
- type: callout
|
||||
title: "Current state"
|
||||
kind: "warning"
|
||||
text: >
|
||||
The investigation has crossed the threshold where a purely Windows
|
||||
explanation is no longer satisfactory. Persistent RaidPort2 failures
|
||||
are directly evidenced, the 1 TB NVMe is not being exposed as a usable
|
||||
disk despite current PCIe/PnP enumeration, and severe AX200 failures
|
||||
repeatedly correlate with some of the more serious NVMe episodes.
|
||||
Hardware isolation is now the highest-value next step.
|
||||
|
||||
- type: bullets
|
||||
items:
|
||||
- "Windows component-store corruption has been repaired."
|
||||
- "Windows protected-file integrity is currently clean."
|
||||
- "Fast Startup has been disabled and cannot explain the September 15 recurrence."
|
||||
- "Persistent NVMe/RaidPort2 instability is confirmed."
|
||||
- "The individual 1 TB SSD has not yet been conclusively proven defective."
|
||||
- "A motherboard/platform fault is now a leading alternative diagnosis."
|
||||
- "AX200 failure is real but is not established as the initiating cause."
|
||||
- "NVRAM/RTC retention remains an independent open diagnostic branch."
|
||||
- "No BIOS flash or TPM clear is currently justified as a first-line diagnostic action."
|
||||
|
||||
- title: "Evidence-preservation considerations"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- >
|
||||
Avoid unnecessary heavy I/O against the 1 TB NVMe before important
|
||||
data is secured.
|
||||
- >
|
||||
Preserve System event logs containing Event 11, 129 and the AX200
|
||||
failure clusters before major firmware or driver changes.
|
||||
- >
|
||||
Record exact wall-clock time of any future freeze before forcing
|
||||
power off whenever possible.
|
||||
- >
|
||||
Change one diagnostic variable at a time. Do not combine SSD reseat,
|
||||
BIOS update, driver replacement and firmware reset into a single
|
||||
intervention.
|
||||
- >
|
||||
Photograph the 1 TB NVMe label and physical installation before
|
||||
reseating or replacement.
|
||||
|
||||
actions_title: "Recommended continuation"
|
||||
|
||||
actions:
|
||||
- title: "Preserve important data"
|
||||
status: "priority"
|
||||
text: >
|
||||
Ensure important user data is backed up before additional storage
|
||||
diagnosis. Do not deliberately stress the suspect 1 TB NVMe merely to
|
||||
reproduce Event 11/129 before data preservation.
|
||||
|
||||
- title: "Perform controlled NVMe physical inspection"
|
||||
status: "pending"
|
||||
text: >
|
||||
Fully shut down the machine using shutdown /s /t 0, disconnect AC and,
|
||||
if servicing procedure permits, disconnect the internal battery before
|
||||
handling the M.2 device. Locate the 1 TB NVMe, photograph its label and
|
||||
installation, inspect the retaining screw, seating, connector area,
|
||||
thermal pad and surrounding PCB for visible abnormalities.
|
||||
|
||||
- title: "Reseat the 1 TB NVMe"
|
||||
status: "pending"
|
||||
text: >
|
||||
Remove and reinstall the NVMe carefully, changing no unrelated BIOS or
|
||||
Windows setting during the same intervention. The purpose is to test the
|
||||
connector/contact branch while preserving diagnostic isolation.
|
||||
|
||||
- title: "Repeat post-reseat enumeration"
|
||||
status: "pending"
|
||||
text: >
|
||||
After reseating, repeat Get-Disk, Get-PhysicalDisk and PresentOnly
|
||||
DiskDrive/SCSIAdapter enumeration. Determine whether the 1 TB device
|
||||
becomes a normal disk, remains PnP-only, or disappears entirely.
|
||||
|
||||
- title: "Review stornvme immediately after reseat"
|
||||
status: "pending"
|
||||
text: >
|
||||
Review stornvme events from the new boot/session for Event 129 resets and
|
||||
Event 11 controller errors. Record exact timestamps and whether the system
|
||||
remains responsive.
|
||||
|
||||
- title: "Perform SSD / slot A-B isolation"
|
||||
status: "pending"
|
||||
text: >
|
||||
If the problem persists, test the suspect 1 TB NVMe in a known-good
|
||||
compatible host or NVMe enclosure and test a known-good compatible NVMe
|
||||
in the Clevo M.2 slot. This is the highest-value test for separating an
|
||||
SSD failure from a motherboard/M.2/PCIe-path failure.
|
||||
|
||||
- title: "Consider temporary operation without suspect NVMe"
|
||||
status: "pending"
|
||||
text: >
|
||||
If operationally practical and the SATA system disk contains the required
|
||||
Windows installation, test system stability with the suspect NVMe
|
||||
physically removed. Continued AX200/platform freezes without the NVMe
|
||||
would materially strengthen the motherboard/platform branch; disappearance
|
||||
of the instability would strengthen the SSD/storage-endpoint branch.
|
||||
|
||||
- title: "Perform firmware/NVRAM retention test separately"
|
||||
status: "pending"
|
||||
text: >
|
||||
Record BIOS date/time and selected harmless settings, save configuration,
|
||||
perform a complete shutdown and leave the system without external power
|
||||
for a controlled interval. Re-enter firmware directly and verify retention.
|
||||
Do not combine this test with the NVMe reseat if avoidable.
|
||||
|
||||
- title: "Do not clear TPM at this stage"
|
||||
status: "deferred"
|
||||
text: >
|
||||
TPM clearing is not currently supported by the storage/PCIe evidence and
|
||||
may introduce recovery-key or device-encryption complications. Preserve
|
||||
the existing TPM state unless later evidence specifically justifies this
|
||||
intervention and recovery information has been secured.
|
||||
|
||||
- title: "Do not perform uncontrolled BIOS update yet"
|
||||
status: "deferred"
|
||||
text: >
|
||||
A BIOS/EC update may eventually become relevant, but hardware isolation,
|
||||
current-firmware documentation and evidence preservation should precede
|
||||
firmware flashing. Do not use a firmware update as a substitute for
|
||||
component isolation.
|
||||
|
||||
- title: "Correlate any future hard freeze"
|
||||
status: "pending"
|
||||
text: >
|
||||
Record the exact wall-clock freeze time. After recovery, review at least
|
||||
five minutes before and after the incident for stornvme, disk, WHEA-Logger,
|
||||
Netwtw10, Kernel-Power, Kernel-PnP, ACPI and related platform events.
|
||||
Particular attention should be paid to whether RaidPort2 and AX200 again
|
||||
fail in the same short interval.
|
||||
|
||||
- title: "Prepare manufacturer escalation evidence"
|
||||
status: "recommended"
|
||||
text: >
|
||||
Preserve a concise manufacturer-facing extract showing the repeated
|
||||
RaidPort2 Event 129/11 history and the March 19, June 8 and September 15
|
||||
coupled NVMe/AX200 failure clusters. Include the observation that the
|
||||
September 15 cluster coincided with a user-observed hard freeze.
|
||||
|
||||
closing: >
|
||||
The investigation now provides strong evidence of a persistent fault in the
|
||||
NVMe/M.2/PCIe storage domain and substantially reduces the likelihood that
|
||||
Windows corruption or Fast Startup alone caused the recurring hard freezes.
|
||||
The 1 TB NVMe SSD remains a major suspect, but the repeated correlation of
|
||||
severe NVMe and Intel AX200 failures across at least three distinct dates
|
||||
raises credible concern for an upstream motherboard, chipset, PCIe, platform
|
||||
power or firmware problem.
|
||||
|
||||
The correct next diagnostic phase is therefore physical and comparative rather
|
||||
than additional broad Windows remediation. Reseating the NVMe provides a
|
||||
low-cost contact test, while A/B testing the suspect SSD and Clevo M.2 slot is
|
||||
required to distinguish endpoint failure from platform failure. Until those
|
||||
tests are completed, neither SSD replacement nor motherboard replacement
|
||||
should be represented as a conclusive diagnosis.
|
||||
|
||||
Diagnostic confidence should be revised after each controlled hardware test.
|
||||
In particular, a suspect SSD that reproduces failure in a known-good host
|
||||
would strongly support SSD replacement; a known-good NVMe that reproduces
|
||||
RaidPort2 failures in this Clevo would strongly support motherboard/platform
|
||||
escalation; and continued cross-device freezes with the suspect NVMe removed
|
||||
would materially increase confidence in a shared platform-level defect.
|
||||