@ -0,0 +1,892 @@
id: "BEF-2026-09-15-CLEVO-DIAG-001"
organization: "Beffroi"
title: "System Stability Investigation — Diagnostic Test Record"
subtitle: "Chronic NVMe controller errors, PCIe device instability and hard-freeze correlation — internal technical notes"
report_type: technical
theme: default
status: "open"
severity: "high"
metadata:
Date: "2026-09-15"
Device: "DESKTOP-SAU019H"
Manufacturer: "PC Specialist / Clevo"
Platform: "NH5x_NH7x_HHx_HJx_HKx"
Motherboard: "CLEVO NHxxHJHK"
BIOS: "Insyde 1.07.07TPCS1 — 2021-09-16"
OS: "Windows 11 Pro — 10.0.26200 / build 26200"
CPU: "Intel Core i7-11800H"
Memory: "16 GB Corsair — single module"
Graphics: "Intel UHD Graphics + NVIDIA GeForce GTX 1650"
SystemDrive: "128GB PCS 2.5\" SATA SSD — serial U9DI16295T"
SecondaryStorage: "1TB PCS PCIe M.2 SSD — NVMe — intermittently unusable from Windows storage stack"
NVMeController: "Silicon Motion PCI VEN_126F DEV_2263 family — Microsoft stornvme"
Wireless: "Intel(R) Wi-Fi 6 AX200 160MHz"
Author: "Maximilien Rigaut"
Purpose: "Internal technical diagnostic notes; preserve evidence and working hypotheses pending hardware isolation"
summary: >
Investigation of DESKTOP-SAU019H has progressed from a general Windows
stability investigation to a substantially more focused hardware/platform
investigation. Windows component-store and protected system-file corruption
identified during the investigation were successfully repaired. A subsequent
SFC validation after reboot reported no integrity violations. Fast Startup
was also disabled to remove the previously demonstrated hybrid-shutdown
failure path from further testing.
Despite establishing this cleaner Windows baseline, the underlying instability
persists. The 1 TB PCS PCIe M.2 SSD and its NVMe controller continue to exhibit
repeated stornvme Event 129 device resets and Event 11 controller errors on
\Device\RaidPort2. These errors are not confined to the September incident:
review of historical event data establishes recurrence across March, June,
September 4, September 14 and September 15 2026.
Windows currently demonstrates an important split in device state. The
Standard NVM Express Controller and the child "1TB PCS PCIe M.2 SSD" can be
enumerated as physically present by Plug and Play, with the controller
reporting Status OK, CM_PROB_NONE and an active PCIe Gen3 x4 link. However,
Get-Disk and Get-PhysicalDisk have failed to expose the 1 TB NVMe as a normal
usable storage device while the 128 GB SATA SSD remains available.
The 2026-09-15 evidence adds a second major dimension to the investigation.
During the hard-freeze episode reported at approximately 09:18-09:20, the
Intel Wi-Fi 6 AX200 also entered a severe failure sequence consisting of an
internal adapter failure, TX/CMD timeout, reports that the adapter was not
functioning correctly, invalid driver-returned values and miniport reset
watchdog events. A stornvme Event 11 against \Device\RaidPort2 occurred
during the same failure cluster.
Historical review identifies comparable coupled NVMe / AX200 episodes on at
least 2026-03-19 and 2026-06-08. This recurrence materially increases concern
that the observed instability may extend beyond an isolated Windows problem
or a single storage-device failure. A failing NVMe SSD remains a credible
explanation for the persistent RaidPort2 failures, but a shared platform-level
fault involving the M.2/PCIe path, motherboard/chipset, platform power
delivery, firmware or another common dependency must now be considered a
leading diagnostic branch.
No single hardware component has yet been conclusively proven defective.
Hardware substitution and isolation testing are required before authorizing
replacement of the SSD, motherboard or other components.
timeline:
- time: "2026-03-17 through 2026-03-26"
event: "Historical NVMe fault activity"
notes: >
Historical System log review shows repeated stornvme Event 129 resets
and/or Event 11 controller errors against \Device\RaidPort2 across
multiple days in March. The storage fault pattern therefore predates the
September investigation by approximately six months.
- time: "2026-03-19 ~08:17-08:20"
event: "Historical coupled NVMe and AX200 failure episode"
notes: >
A RaidPort2 reset was recorded at approximately 08:17:31. Roughly
one and a half minutes later the Intel Wi-Fi 6 AX200 entered a failure
sequence including Event 5005 internal failure, Event 5007 TX/CMD timeout,
Event 5002 adapter-not-functioning reports and Event 5032 miniport reset
watchdog activity. stornvme subsequently recorded Event 11 against
\Device\RaidPort2 at approximately 08:19:26. This is the earliest
currently identified example of storage and wireless failures clustering
in the same short time interval.
- time: "2026-06-08 ~12:10-12:16"
event: "Second historical coupled NVMe and AX200 failure episode"
notes: >
RaidPort2 reset events occurred at approximately 12:10:31 and 12:12:09.
At approximately 12:13:11 the AX200 experienced another TX/CMD timeout
and associated adapter/reset-watchdog failures. Another NVMe reset was
issued at approximately 12:14:01 followed by stornvme Event 11 at
approximately 12:14:04. Additional storage and wireless fault activity
continued within the same incident window. The similarity to the March
and September sequences materially strengthens the correlation.
- time: "2026-06-09"
event: "Additional historical RaidPort2 errors"
notes: >
Additional stornvme Event 129 / Event 11 activity was identified without
requiring a simultaneous AX200 failure. This demonstrates that storage
instability can occur independently of the wireless failure sequence.
- time: "2026-09-04 before ~17:23"
event: "Hard-freeze incident"
notes: >
System experienced a hard freeze before approximately 17:23. Exact freeze
onset was not timestamped.
- time: "2026-09-04 ~17:25"
event: "Second hard-freeze / hang"
notes: >
A second hang was observed at approximately 17:25. Normal shutdown could
not subsequently be completed and a forced power-off was required.
- time: "2026-09-04"
event: "Firmware/NVRAM warning observed"
notes: >
Firmware displayed "A first boot or NVRAM reset condition has been
detected." This remains an independent unresolved firmware-state finding.
The warning alone does not establish failure of the RTC/CMOS battery.
- time: "2026-09-04"
event: "Fast Startup failure identified"
notes: >
Kernel-Boot Event 29 recorded a Fast Startup failure with status
0xC000007B. Restart and a full shutdown bypassing Fast Startup subsequently
completed successfully.
- time: "2026-09-04"
event: "RaidPort2 errors identified"
notes: >
System logs showed repeated stornvme Event 129 resets and Event 11
controller errors against \Device\RaidPort2 around the incident period.
At this stage the responsible physical storage device had not yet been
conclusively isolated.
- time: "2026-09-14"
event: "Fast Startup disabled for controlled diagnosis"
notes: >
powercfg /h off completed successfully. This disables hibernation and
Windows Fast Startup, removing the previously abnormal hybrid-shutdown
path as a variable during subsequent testing.
- time: "2026-09-14"
event: "Windows component-store repair"
notes: >
DISM /Online /Cleanup-Image /RestoreHealth completed at 100 percent with
"The restore operation completed successfully" and "The operation
completed successfully."
- time: "2026-09-14"
event: "Windows protected-file repair"
notes: >
sfc /scannow found corrupt Windows files and successfully repaired them.
- time: "2026-09-14 after reboot"
event: "Post-repair Windows integrity verification"
notes: >
A subsequent sfc /scannow reported "Windows Resource Protection did not
find any integrity violations." The Windows integrity repair therefore
remained clean across the reboot.
- time: "2026-09-14"
event: "Storage inventory discrepancy identified"
notes: >
Get-Disk and Get-PhysicalDisk exposed only the 128 GB PCS 2.5-inch SATA
SSD. The expected 1 TB PCS PCIe M.2 SSD was not exposed as a normal disk.
- time: "2026-09-14"
event: "NVMe controller positively enumerated"
notes: >
Get-PnpDevice -PresentOnly enumerated a Standard NVM Express Controller
using PCI identifier VEN_126F&DEV_2263. The controller reported Status OK
and was bound to the Microsoft stornvme driver.
- time: "2026-09-14"
event: "1 TB NVMe child device positively enumerated"
notes: >
Get-PnpDevice -PresentOnly -Class DiskDrive enumerated
"1TB PCS PCIe M.2 SSD" with Status OK. The 128 GB SATA SSD was also
present.
- time: "2026-09-14"
event: "NVMe PnP state inspected"
notes: >
Detailed controller properties reported Present True, HasProblem False,
CM_PROB_NONE and ConfigManagerErrorCode CM_PROB_NONE. Windows therefore
did not consider the PCI device absent or in a conventional PnP error
state.
- time: "2026-09-14"
event: "NVMe PCIe link inspected"
notes: >
Controller properties identified PCI bus 2, device 0, function 0 with
current link speed 3 and link width 4, matching maximum link speed 3 and
width 4. The NVMe controller was therefore actively linked at PCIe Gen3
x4 during inspection.
- time: "2026-09-14 16:23:21"
event: "Fresh stornvme controller error"
notes: >
stornvme Event 11 reported "The driver detected a controller error on
\Device\RaidPort2." This occurred after Windows repair and while the NVMe
controller was currently enumerated.
- time: "2026-09-15 08:54:49"
event: "Current diagnostic boot"
notes: >
Intel AX200 initialization events were recorded during the current boot.
The adapter initially entered service normally.
- time: "2026-09-15 08:55:20"
event: "RaidPort2 reset"
notes: >
stornvme Event 129 reported "Reset to device, \Device\RaidPort2, was
issued."
- time: "2026-09-15 08:56:23"
event: "Second RaidPort2 reset"
notes: >
A second stornvme Event 129 reset was issued against \Device\RaidPort2
approximately one minute after the first.
- time: "2026-09-15 08:58:17"
event: "RaidPort2 controller error"
notes: >
stornvme Event 11 reported a controller error against
\Device\RaidPort2. The storage path was therefore already producing
errors well before the later hard freeze.
- time: "2026-09-15 ~09:18-09:20"
event: "Hard system freeze"
notes: >
User observed another hard system freeze. The event-log cluster immediately
surrounding this incident contains simultaneous severe AX200 and NVMe
storage failures.
- time: "2026-09-15 09:19:52"
event: "AX200 severe failure begins"
notes: >
Netwtw10 Event 5005 reported that Intel(R) Wi-Fi 6 AX200 160MHz
encountered an internal error and failed. Event 5007 reported a TX/CMD
timeout with a hung TfdQueue.
- time: "2026-09-15 09:19:53-09:19:57"
event: "AX200 failure and recovery cascade"
notes: >
The AX200 generated Event 5002 reports stating that the adapter was not
functioning properly, followed by a large burst of Event 5010 messages
reporting invalid values returned to the driver. Event 5032 subsequently
recorded Driver Miniport reset watchdog failures. This represents a
substantive adapter/driver/device communication failure rather than a
routine Wi-Fi disconnect.
- time: "2026-09-15 09:19:56"
event: "NVMe controller error during AX200 failure cluster"
notes: >
stornvme Event 11 reported "The driver detected a controller error on
\Device\RaidPort2" during the same second as the AX200 Event 5010 storm.
The temporal coincidence is diagnostically significant, particularly
because comparable clustering is present in March and June historical
logs.
findings:
- title: "Chronic RaidPort2 / NVMe storage-path instability"
severity: "high"
status: "confirmed"
evidence: >
Repeated stornvme Event 129 device resets and Event 11 controller errors
against \Device\RaidPort2 occur across multiple months, including March,
June, September 4, September 14 and September 15 2026. Fresh resets and
controller errors continue after Windows component-store and system-file
repair.
assessment: >
The recurrence establishes a persistent low-level storage-path problem.
This is no longer reasonably explained as a single transient Windows
incident. The evidence demonstrates failure somewhere in the NVMe device /
M.2 slot / PCIe path / associated platform stack, but does not by itself
identify which physical component is defective.
- title: "1 TB NVMe is enumerated but not exposed as a usable disk"
severity: "high"
status: "confirmed"
evidence: >
PresentOnly PnP enumeration identifies both the Standard NVM Express
Controller and its 1TB PCS PCIe M.2 SSD child device. The controller
reports Status OK, CM_PROB_NONE and an active PCIe Gen3 x4 link. Despite
this, Get-Disk and Get-PhysicalDisk expose only the 128 GB SATA SSD.
assessment: >
PCIe enumeration alone is therefore not evidence that the NVMe storage
device is operational. The controller can establish a PCIe/PnP presence
while the storage stack is unable to expose the underlying media as a
normal disk. This strongly implicates the NVMe storage path.
- title: "Severe Intel AX200 failure correlated with September 15 freeze"
severity: "high"
status: "confirmed"
evidence: >
During the September 15 hard-freeze window, the AX200 generated Event
5005 internal failures, Event 5007 TX/CMD timeout, Event 5002
adapter-not-functioning reports, a very large Event 5010 invalid-value
burst and Event 5032 miniport reset watchdog failures.
assessment: >
The wireless subsystem experienced a genuine low-level failure during
the freeze interval. This does not prove that the AX200 caused the system
freeze. Its diagnostic importance is primarily the temporal correlation
with the concurrent NVMe controller failure.
- title: "Repeated cross-device NVMe / AX200 failure correlation"
severity: "high"
status: "confirmed-correlation"
evidence: >
Comparable short-window clustering of RaidPort2 reset/controller errors
and severe AX200 failures has now been identified on at least three
distinct dates: 2026-03-19, 2026-06-08 and 2026-09-15.
assessment: >
Repetition on three separated dates makes accidental one-time temporal
coincidence substantially less plausible. The evidence establishes a
repeatable correlation, not causation. A common platform dependency,
platform power issue, PCIe/chipset problem, firmware interaction or a
severe fault in one device disrupting the wider platform are credible
explanations requiring hardware isolation.
- title: "RaidPort2 failures also occur without visible AX200 failure"
severity: "medium"
status: "confirmed"
evidence: >
RaidPort2 resets/controller errors are present on additional dates where
the reviewed event window does not show a corresponding severe AX200
failure cluster.
assessment: >
The NVMe/storage problem therefore has an independent persistent
manifestation. The AX200 correlation appears to accompany some severe
incidents rather than every storage-path fault. This prevents treating
the AX200 as a necessary cause of every RaidPort2 event.
- title: "Windows component-store corruption"
severity: "medium"
status: "repaired"
evidence: >
DISM /Online /Cleanup-Image /RestoreHealth completed successfully.
assessment: >
Windows corruption was genuine but has been repaired. Continued
stornvme failures after repair substantially weaken Windows component-store
corruption as the primary explanation for the continuing hardware
symptoms.
- title: "Protected Windows system-file corruption"
severity: "medium"
status: "repaired-and-verified"
evidence: >
sfc /scannow initially found and repaired corrupt files. A subsequent SFC
run after reboot reported no integrity violations.
assessment: >
Windows protected-file integrity is currently clean. Earlier corruption
may have resulted from forced power-offs or storage instability, may have
contributed to instability, or may have been unrelated. Direction of
causality is not established.
- title: "Fast Startup failure"
severity: "medium"
status: "mitigated-for-diagnosis"
evidence: >
Earlier Kernel-Boot Event 29 identified a Fast Startup failure with status
0xC000007B. powercfg /h off was subsequently used successfully.
assessment: >
Fast Startup was a real abnormality but is now removed from the diagnostic
path. The persistence of storage errors and another hard freeze with
hibernation/Fast Startup disabled demonstrates that Fast Startup cannot
explain the entire incident.
- title: "Firmware / NVRAM reset warning"
severity: "medium"
status: "open"
evidence: >
Firmware previously displayed "A first boot or NVRAM reset condition has
been detected."
assessment: >
This remains unresolved. The warning is insufficient by itself to diagnose
a failed RTC/CMOS battery. A retention test is still required. Given the
emerging possibility of a platform-level fault, the firmware finding
should remain visible rather than being dismissed as unrelated.
- title: "BIOS storage visibility"
severity: "medium"
status: "inconclusive"
evidence: >
During manual BIOS inspection, the expected 1 TB NVMe was not visibly
listed in the inspected storage menus.
assessment: >
This observation is useful but not conclusive because the exact Clevo /
Insyde firmware interface may not expose NVMe inventory in the inspected
menu. Windows subsequently demonstrated physical PCIe/PnP enumeration of
the NVMe controller and child disk. BIOS-menu absence must therefore not
be treated as proof that the PCIe device failed firmware enumeration.
- title: "128 GB SATA SSD remains normally exposed"
severity: "info"
status: "currently-operational"
evidence: >
Get-Disk and Get-PhysicalDisk consistently expose the 128GB PCS 2.5-inch
SATA SSD as Online / Healthy / OK. Reliability telemetry reported
approximately 2033 power-on hours, 40 C temperature, wear 0 and no
reported total or uncorrected read errors.
assessment: >
Available telemetry does not presently implicate the SATA system disk in
the same manner as the missing NVMe device. These counters must not be
mistakenly attributed to the 1 TB NVMe.
diagnostics:
confidence_scale:
type: "investigator-estimate"
range: "0-100"
interpretation: >
Confidence values below are engineering diagnostic estimates derived from
the currently available evidence. They are not statistical probabilities,
failure-rate calculations or manufacturer test results. They express the
relative strength of each working hypothesis and should be revised after
hardware isolation testing.
hypotheses:
- id: "D1"
diagnosis: "Persistent fault in the 1 TB NVMe / M.2 / PCIe storage path"
confidence: "very-high"
confidence_percent: 95
scope: "fault-domain"
status: "strongly-supported"
evidence_for:
- "Repeated stornvme Event 129 resets across multiple months."
- "Repeated stornvme Event 11 controller errors across multiple months."
- "Fresh Event 129 and Event 11 activity after Windows repair."
- "1 TB NVMe PnP device is present while Get-Disk does not expose usable media."
- "NVMe controller can establish PCIe Gen3 x4 while storage functionality remains unavailable."
evidence_against:
- "PnP controller reports Status OK and CM_PROB_NONE."
- "No hardware substitution test has yet identified the exact failed element."
interpretation: >
Confidence is high that the fault domain includes the 1 TB NVMe storage
path. This does not mean there is 95 percent confidence that the SSD
module itself is defective; SSD, connector, slot, motherboard path,
power and firmware remain inside this fault domain.
tests_to_confirm:
- "Reseat the 1 TB NVMe and repeat enumeration/event checks."
- "Test the suspect NVMe in a known-good compatible system or enclosure."
- "Test a known-good compatible NVMe in the Clevo M.2 slot."
- id: "D2"
diagnosis: "Failure of the 1 TB NVMe SSD module itself"
confidence: "moderate-high"
confidence_percent: 70
scope: "component"
status: "probable-but-unconfirmed"
evidence_for:
- "Persistent controller resets/errors associated with its storage path."
- "Device can enumerate while usable disk media is unavailable."
- "Symptoms recur over several months."
evidence_against:
- "The controller establishes a normal-width PCIe Gen3 x4 link."
- "No direct SMART/health telemetry from the missing NVMe has been obtained."
- "A defective M.2 slot, motherboard path or power source can produce similar symptoms."
- "Concurrent AX200 failures raise concern about a wider platform issue."
interpretation: >
The SSD remains a strong individual-component suspect but should not yet
be condemned solely from stornvme Event 11/129. A/B substitution is
required before assigning the fault specifically to the SSD.
tests_to_confirm:
- "Test suspect SSD externally or in another known-good PCIe/NVMe host."
- "Install a known-good NVMe in the Clevo slot and monitor Event 11/129."
- id: "D3"
diagnosis: "Motherboard / chipset / shared PCIe platform instability"
confidence: "moderate-high"
confidence_percent: 75
scope: "platform"
status: "leading-alternative"
evidence_for:
- "At least three dates show temporally coupled NVMe and AX200 severe failures."
- "September 15 includes simultaneous NVMe Event 11 and AX200 failure storm during a hard freeze."
- "March and June historical logs show similar cross-device clustering."
- "Firmware/NVRAM anomaly exists as an additional unresolved platform-level observation."
evidence_against:
- "RaidPort2 failures also occur without a severe AX200 failure."
- "No WHEA evidence currently proves PCIe root-port or chipset failure."
- "A severely malfunctioning endpoint device can potentially destabilize software or shared platform resources without the motherboard being defective."
- "No known-good-device substitution test has yet reproduced the failure."
interpretation: >
Cross-device recurrence materially raises the motherboard/platform branch
above a speculative possibility. It is now a leading alternative to an
isolated SSD failure, but direct evidence identifying a motherboard
component is still absent.
tests_to_confirm:
- "Known-good NVMe in Clevo slot."
- "Suspect NVMe in known-good host."
- "If possible, operate Clevo temporarily without suspect NVMe and monitor stability."
- "Review PCIe root-port, WHEA and ACPI/platform events during any future incident."
- "Correlate AX200 and NVMe physical PCIe topology where possible."
- id: "D4"
diagnosis: "Shared platform power-delivery instability"
confidence: "moderate"
confidence_percent: 60
scope: "platform"
status: "plausible"
evidence_for:
- "Multiple PCIe-connected devices have demonstrated severe failures in the same short windows."
- "Hard freezes are compatible with severe platform-level power or bus disruption."
- "Firmware/NVRAM anomaly provides an additional reason to retain power-state/platform hypotheses."
evidence_against:
- "No voltage measurement or rail telemetry is available."
- "No direct power-controller fault has been logged."
- "The storage fault can occur without simultaneous AX200 failure."
interpretation: >
Power delivery is a credible mechanism for correlated endpoint failures
but is presently inferred rather than directly measured.
tests_to_confirm:
- "Repeat testing with known-good AC adapter if available and electrically compatible."
- "Inspect motherboard and M.2 area for physical damage or thermal evidence."
- "Compare behavior with suspect NVMe removed."
- "Escalate to board-level diagnosis if substitution testing clears the SSD."
- id: "D5"
diagnosis: "Firmware / BIOS / EC interaction affecting PCIe or power state"
confidence: "moderate"
confidence_percent: 50
scope: "platform-firmware"
status: "plausible-unconfirmed"
evidence_for:
- "Firmware previously reported a first-boot / NVRAM-reset condition."
- "Failures involve devices whose state is affected by platform firmware and power management."
- "System firmware dates from 2021 while current Windows and drivers are substantially newer."
evidence_against:
- "No firmware-specific error directly explains RaidPort2 failures."
- "No BIOS/EC update comparison has been performed."
- "No evidence currently proves that the NVRAM warning and PCIe failures share a cause."
interpretation: >
Firmware remains relevant but should not currently outrank the directly
evidenced NVMe fault domain. Firmware update should not be used as the
first uncontrolled intervention because doing so would alter the
diagnostic baseline.
tests_to_confirm:
- "Perform NVRAM/RTC retention test."
- "Document current BIOS configuration and exact firmware availability."
- "Consider firmware update only after evidence preservation, hardware isolation and recovery preparation."
- id: "D6"
diagnosis: "Intel AX200 is the primary root cause of the system freezes"
confidence: "low-moderate"
confidence_percent: 30
scope: "component"
status: "possible-but-not-leading"
evidence_for:
- "AX200 enters severe TX/CMD timeout and reset-watchdog failure during the September 15 freeze."
- "Comparable AX200 failure clusters exist in March and June."
evidence_against:
- "Chronic RaidPort2 failures occur independently on many dates."
- "Storage errors pre-exist some AX200 failure clusters."
- "A concurrent failure does not establish that AX200 initiated the incident."
- "The missing/unusable 1 TB NVMe is independently abnormal."
interpretation: >
The AX200 is demonstrably failing during some incidents, but current
evidence more strongly supports treating it as either another victim of
a shared platform fault or a secondary contributor rather than the sole
root cause.
- id: "D7"
diagnosis: "Windows corruption / Fast Startup as primary remaining root cause"
confidence: "low"
confidence_percent: 10
scope: "software"
status: "substantially-deprioritized"
evidence_for:
- "Windows component-store and protected-file corruption were previously confirmed."
- "Fast Startup previously failed."
evidence_against:
- "DISM repair completed successfully."
- "SFC repair completed successfully."
- "Post-reboot SFC reported no integrity violations."
- "Fast Startup was disabled."
- "Fresh RaidPort2 errors occurred after repair."
- "Another hard freeze occurred after establishing the cleaner software baseline."
- "Storage failure history spans multiple months."
interpretation: >
Windows problems were real and warranted repair, but they no longer
provide a satisfactory primary explanation for the persistent incident.
They may instead be consequences or secondary effects of storage errors
and forced shutdowns.
- id: "D8"
diagnosis: "RTC/CMOS battery or NVRAM-retention fault"
confidence: "low-moderate"
confidence_percent: 35
scope: "firmware-retention"
status: "open"
evidence_for:
- "Firmware displayed a first-boot / NVRAM-reset warning."
evidence_against:
- "A single NVRAM warning does not establish RTC battery failure."
- "No controlled retention test has yet demonstrated loss of clock or settings."
- "No direct link between RTC retention and RaidPort2/AX200 failures is established."
interpretation: >
This remains a separate open diagnostic branch. It may eventually
contribute to a broader motherboard diagnosis, but the current evidence
does not justify combining the two findings.
tests_to_confirm:
- "Record BIOS clock and settings."
- "Perform complete shutdown and remove external power for a controlled interval."
- "Re-enter BIOS directly and verify clock/settings retention."
- "Record whether the NVRAM warning recurs."
current_leading_assessment:
confidence: "high"
statement: >
A persistent hardware-level or platform-level fault is now more likely
than a purely Windows/software root cause. The strongest directly evidenced
fault domain is the 1 TB NVMe / M.2 / PCIe storage path. However, repeated
temporal correlation between severe NVMe and AX200 failures makes an
upstream motherboard/chipset/power/firmware problem sufficiently plausible
that the SSD should not be replaced as a conclusively diagnosed component
without A/B hardware testing.
not_yet_supported:
- "The 1 TB SSD is definitively defective."
- "The Clevo motherboard is definitively defective."
- "The Intel AX200 caused the hard freezes."
- "The CMOS/RTC battery caused the NVRAM warning."
- "The NVRAM warning and NVMe failures have a common cause."
- "A BIOS update will resolve the problem."
- "Windows corruption caused the original freezes."
- "The SATA SSD is responsible for the RaidPort2 events."
sections:
- title: "Commands and results — Windows baseline"
content:
- type: bullets
items:
- >
powercfg /h off — completed successfully; hibernation and Fast
Startup disabled.
- >
DISM /Online /Cleanup-Image /RestoreHealth — completed successfully.
- >
sfc /scannow — corrupt files found and repaired.
- >
Post-reboot sfc /scannow — no integrity violations detected.
- >
Windows repair is therefore retained as completed remediation, not
as proof of root cause.
- title: "Commands and results — storage enumeration"
content:
- type: bullets
items:
- >
Get-Disk — only the 128GB PCS 2.5-inch SATA SSD exposed as a normal
disk during the affected state.
- >
Get-PhysicalDisk — only the 128 GB SATA device exposed.
- >
Get-PnpDevice -PresentOnly -Class SCSIAdapter — Standard NVM Express
Controller present and Status OK.
- >
Get-PnpDevice -PresentOnly -Class DiskDrive — both 1TB PCS PCIe M.2
SSD and 128GB PCS 2.5-inch SSD enumerated with Status OK.
- >
NVMe controller properties — Present True, HasProblem False,
CM_PROB_NONE, Microsoft stornvme.
- >
PCIe properties — active Gen3 x4 link, matching the controller's
reported maximum Gen3 x4 capability.
- >
The discrepancy between PnP presence and Get-Disk usability is a
central diagnostic finding.
- title: "Commands and results — storage event history"
content:
- type: bullets
items:
- >
stornvme Event 129 repeatedly reports resets to
\Device\RaidPort2.
- >
stornvme Event 11 repeatedly reports controller errors on
\Device\RaidPort2.
- >
Events recur across March, June and September 2026.
- >
September 14 produced a fresh Event 11 after Windows repair.
- >
September 15 produced Event 129 at 08:55:20 and 08:56:23,
Event 11 at 08:58:17, and another Event 11 at 09:19:56 during
the hard-freeze/AX200 failure window.
- title: "Commands and results — wireless correlation"
content:
- type: bullets
items:
- >
September 15 09:19:52 — AX200 Event 5005 internal failure and
Event 5007 TX/CMD timeout.
- >
September 15 09:19:53 onward — Event 5002 reports adapter not
functioning correctly.
- >
September 15 09:19:56 — large Event 5010 invalid-value burst.
- >
September 15 09:19:56 — stornvme Event 11 occurs during the same
second as the AX200 Event 5010 storm.
- >
September 15 09:19:57 — AX200 Event 5032 Driver Miniport reset
watchdog failures.
- >
Comparable short-window NVMe / AX200 failure clustering was found
on March 19 and June 8.
- title: "Interpretation at this checkpoint"
content:
- type: callout
title: "Current state"
kind: "warning"
text: >
The investigation has crossed the threshold where a purely Windows
explanation is no longer satisfactory. Persistent RaidPort2 failures
are directly evidenced, the 1 TB NVMe is not being exposed as a usable
disk despite current PCIe/PnP enumeration, and severe AX200 failures
repeatedly correlate with some of the more serious NVMe episodes.
Hardware isolation is now the highest-value next step.
- type: bullets
items:
- "Windows component-store corruption has been repaired."
- "Windows protected-file integrity is currently clean."
- "Fast Startup has been disabled and cannot explain the September 15 recurrence."
- "Persistent NVMe/RaidPort2 instability is confirmed."
- "The individual 1 TB SSD has not yet been conclusively proven defective."
- "A motherboard/platform fault is now a leading alternative diagnosis."
- "AX200 failure is real but is not established as the initiating cause."
- "NVRAM/RTC retention remains an independent open diagnostic branch."
- "No BIOS flash or TPM clear is currently justified as a first-line diagnostic action."
- title: "Evidence-preservation considerations"
content:
- type: bullets
items:
- >
Avoid unnecessary heavy I/O against the 1 TB NVMe before important
data is secured.
- >
Preserve System event logs containing Event 11, 129 and the AX200
failure clusters before major firmware or driver changes.
- >
Record exact wall-clock time of any future freeze before forcing
power off whenever possible.
- >
Change one diagnostic variable at a time. Do not combine SSD reseat,
BIOS update, driver replacement and firmware reset into a single
intervention.
- >
Photograph the 1 TB NVMe label and physical installation before
reseating or replacement.
actions_title: "Recommended continuation"
actions:
- title: "Preserve important data"
status: "priority"
text: >
Ensure important user data is backed up before additional storage
diagnosis. Do not deliberately stress the suspect 1 TB NVMe merely to
reproduce Event 11/129 before data preservation.
- title: "Perform controlled NVMe physical inspection"
status: "pending"
text: >
Fully shut down the machine using shutdown /s /t 0, disconnect AC and,
if servicing procedure permits, disconnect the internal battery before
handling the M.2 device. Locate the 1 TB NVMe, photograph its label and
installation, inspect the retaining screw, seating, connector area,
thermal pad and surrounding PCB for visible abnormalities.
- title: "Reseat the 1 TB NVMe"
status: "pending"
text: >
Remove and reinstall the NVMe carefully, changing no unrelated BIOS or
Windows setting during the same intervention. The purpose is to test the
connector/contact branch while preserving diagnostic isolation.
- title: "Repeat post-reseat enumeration"
status: "pending"
text: >
After reseating, repeat Get-Disk, Get-PhysicalDisk and PresentOnly
DiskDrive/SCSIAdapter enumeration. Determine whether the 1 TB device
becomes a normal disk, remains PnP-only, or disappears entirely.
- title: "Review stornvme immediately after reseat"
status: "pending"
text: >
Review stornvme events from the new boot/session for Event 129 resets and
Event 11 controller errors. Record exact timestamps and whether the system
remains responsive.
- title: "Perform SSD / slot A-B isolation"
status: "pending"
text: >
If the problem persists, test the suspect 1 TB NVMe in a known-good
compatible host or NVMe enclosure and test a known-good compatible NVMe
in the Clevo M.2 slot. This is the highest-value test for separating an
SSD failure from a motherboard/M.2/PCIe-path failure.
- title: "Consider temporary operation without suspect NVMe"
status: "pending"
text: >
If operationally practical and the SATA system disk contains the required
Windows installation, test system stability with the suspect NVMe
physically removed. Continued AX200/platform freezes without the NVMe
would materially strengthen the motherboard/platform branch; disappearance
of the instability would strengthen the SSD/storage-endpoint branch.
- title: "Perform firmware/NVRAM retention test separately"
status: "pending"
text: >
Record BIOS date/time and selected harmless settings, save configuration,
perform a complete shutdown and leave the system without external power
for a controlled interval. Re-enter firmware directly and verify retention.
Do not combine this test with the NVMe reseat if avoidable.
- title: "Do not clear TPM at this stage"
status: "deferred"
text: >
TPM clearing is not currently supported by the storage/PCIe evidence and
may introduce recovery-key or device-encryption complications. Preserve
the existing TPM state unless later evidence specifically justifies this
intervention and recovery information has been secured.
- title: "Do not perform uncontrolled BIOS update yet"
status: "deferred"
text: >
A BIOS/EC update may eventually become relevant, but hardware isolation,
current-firmware documentation and evidence preservation should precede
firmware flashing. Do not use a firmware update as a substitute for
component isolation.
- title: "Correlate any future hard freeze"
status: "pending"
text: >
Record the exact wall-clock freeze time. After recovery, review at least
five minutes before and after the incident for stornvme, disk, WHEA-Logger,
Netwtw10, Kernel-Power, Kernel-PnP, ACPI and related platform events.
Particular attention should be paid to whether RaidPort2 and AX200 again
fail in the same short interval.
- title: "Prepare manufacturer escalation evidence"
status: "recommended"
text: >
Preserve a concise manufacturer-facing extract showing the repeated
RaidPort2 Event 129/11 history and the March 19, June 8 and September 15
coupled NVMe/AX200 failure clusters. Include the observation that the
September 15 cluster coincided with a user-observed hard freeze.
closing: >
The investigation now provides strong evidence of a persistent fault in the
NVMe/M.2/PCIe storage domain and substantially reduces the likelihood that
Windows corruption or Fast Startup alone caused the recurring hard freezes.
The 1 TB NVMe SSD remains a major suspect, but the repeated correlation of
severe NVMe and Intel AX200 failures across at least three distinct dates
raises credible concern for an upstream motherboard, chipset, PCIe, platform
power or firmware problem.
The correct next diagnostic phase is therefore physical and comparative rather
than additional broad Windows remediation. Reseating the NVMe provides a
low-cost contact test, while A/B testing the suspect SSD and Clevo M.2 slot is
required to distinguish endpoint failure from platform failure. Until those
tests are completed, neither SSD replacement nor motherboard replacement
should be represented as a conclusive diagnosis.
Diagnostic confidence should be revised after each controlled hardware test.
In particular, a suspect SSD that reproduces failure in a known-good host
would strongly support SSD replacement; a known-good NVMe that reproduces
RaidPort2 failures in this Clevo would strongly support motherboard/platform
escalation; and continued cross-device freezes with the suspect NVMe removed
would materially increase confidence in a shared platform-level defect.