Updated reports
Report CI typst_reporter passed all CI checks.
Beffroi/typst_reporter/pipeline/head This commit looks good
Details
Report CI typst_reporter passed all CI checks.
Beffroi/typst_reporter/pipeline/head This commit looks good
Details
This commit is contained in:
parent
2b6cdb5a23
commit
49c0c483a0
|
|
@ -452,7 +452,7 @@
|
|||
|
||||
block(
|
||||
width: 100%,
|
||||
breakable: true,
|
||||
breakable: false,
|
||||
inset: 8pt,
|
||||
stroke: 0.5pt + theme-color(theme, "line"),
|
||||
radius: 2pt,
|
||||
|
|
|
|||
|
|
@ -1,29 +0,0 @@
|
|||
{
|
||||
"schema_version": 1,
|
||||
"report_type": "windows_system_maintenance",
|
||||
"mode": "Legacy",
|
||||
"generated_at": null,
|
||||
"completed_at": null,
|
||||
"host": {
|
||||
"computer_name": null,
|
||||
"user_name": null,
|
||||
"administrator": null,
|
||||
"powershell_version": null
|
||||
},
|
||||
"parameters": {
|
||||
"event_log_days": null,
|
||||
"max_event_errors": null
|
||||
},
|
||||
"warnings": [
|
||||
"Converted from legacy formatted TXT; some fields may be approximate.",
|
||||
"Sections marked legacy_parsed were reconstructed from presentation output."
|
||||
],
|
||||
"summary": null,
|
||||
"sections": {},
|
||||
"legacy": {
|
||||
"source_format": "WinDiagnostics text report",
|
||||
"source_file": "2026-09-04-clevo-handoff.yaml",
|
||||
"original_report_path": null,
|
||||
"converter": "legacy_windiag_to_json.py"
|
||||
}
|
||||
}
|
||||
|
|
@ -0,0 +1,140 @@
|
|||
id: "BEF-2026-09-15-DIAG-SYNTHESIS"
|
||||
|
||||
organization: "Beffroi"
|
||||
|
||||
title: "Rapport de diagnostic — Instabilité du poste"
|
||||
subtitle: "Synthèse des causes probables et état de l'investigation"
|
||||
|
||||
report_type: "briefing"
|
||||
theme: "default"
|
||||
|
||||
status: "open"
|
||||
severity: "high"
|
||||
|
||||
metadata:
|
||||
Date: "2026-09-15"
|
||||
Appareil: "DESKTOP-SAU019H"
|
||||
Constructeur: "PC Specialist / Clevo"
|
||||
État: "Fonctionnel mais instable"
|
||||
Author: "Maximilien Rigaut"
|
||||
|
||||
summary: >
|
||||
Les investigations indiquent désormais une panne matérielle probable autour
|
||||
du stockage NVMe / PCIe. Les erreurs persistent après réparation de Windows
|
||||
et sont présentes dans les journaux depuis plusieurs mois.
|
||||
|
||||
Lors du dernier gel complet, le SSD NVMe et la carte Wi-Fi ont rencontré des
|
||||
erreurs sévères quasi simultanément. Le même comportement a été retrouvé lors
|
||||
d'incidents précédents.
|
||||
|
||||
Le SSD NVMe reste le premier composant suspect, mais une défaillance plus
|
||||
générale de la carte mère / plateforme PCIe est désormais également probable.
|
||||
Un test matériel croisé est nécessaire pour départager ces deux scénarios.
|
||||
|
||||
diagnostics:
|
||||
confidence_scale:
|
||||
interpretation: >
|
||||
Les pourcentages représentent notre niveau de confiance actuel dans chaque
|
||||
piste, et non une probabilité statistique de panne.
|
||||
|
||||
hypotheses:
|
||||
- diagnosis: "Panne dans la chaîne NVMe / PCIe"
|
||||
confidence_percent: 95
|
||||
status: "quasi certain"
|
||||
interpretation: >
|
||||
Les erreurs NVMe sont répétées sur plusieurs mois et persistent après
|
||||
réparation de Windows.
|
||||
|
||||
- diagnosis: "SSD NVMe 1 To défectueux"
|
||||
confidence_percent: 70
|
||||
status: "probable"
|
||||
interpretation: >
|
||||
Le SSD est détecté matériellement mais n'est plus présenté normalement
|
||||
comme disque utilisable. Son remplacement pourrait résoudre le problème.
|
||||
|
||||
- diagnosis: "Carte mère / plateforme PCIe défectueuse"
|
||||
confidence_percent: 75
|
||||
status: "probable"
|
||||
interpretation: >
|
||||
Lors d'au moins trois incidents distincts, le NVMe et la carte Wi-Fi
|
||||
ont rencontré des défaillances sévères dans la même fenêtre temporelle.
|
||||
Cela suggère qu'un élément commun de la plateforme peut être impliqué.
|
||||
|
||||
- diagnosis: "Windows comme cause principale"
|
||||
confidence_percent: 10
|
||||
status: "peu probable"
|
||||
interpretation: >
|
||||
Windows a été réparé et vérifié. Les erreurs matérielles et les gels
|
||||
ont continué après cette intervention.
|
||||
|
||||
findings:
|
||||
- title: "Défaillance NVMe persistante"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
assessment: >
|
||||
Les erreurs du contrôleur NVMe sont présentes dans les journaux depuis
|
||||
plusieurs mois et continuent après réparation de Windows.
|
||||
|
||||
- title: "Corrélation avec d'autres périphériques"
|
||||
severity: "high"
|
||||
status: "confirmed-correlation"
|
||||
assessment: >
|
||||
En mars, juin et septembre, des défaillances NVMe et Wi-Fi sévères ont
|
||||
été observées dans les mêmes fenêtres temporelles. Le dernier épisode
|
||||
correspond directement à un gel complet observé par l'utilisateur.
|
||||
|
||||
- title: "Windows réparé"
|
||||
severity: "info"
|
||||
status: "resolved"
|
||||
assessment: >
|
||||
DISM et SFC ont réparé les corruptions détectées. Les vérifications
|
||||
suivantes sont propres et le problème persiste.
|
||||
|
||||
sections:
|
||||
- title: "Impact"
|
||||
content:
|
||||
- type: callout
|
||||
title: "Poste non fiable"
|
||||
kind: "warning"
|
||||
text: >
|
||||
Le poste reste utilisable mais peut subir un gel complet sans
|
||||
avertissement. Il existe un risque de perte de travail et de
|
||||
corruption lors des arrêts forcés.
|
||||
|
||||
- title: "Décision à prendre"
|
||||
content:
|
||||
- type: callout
|
||||
title: "SSD ou carte mère ?"
|
||||
kind: "info"
|
||||
text: >
|
||||
Nous avons suffisamment d'éléments pour privilégier une panne
|
||||
matérielle, mais pas encore pour décider si le remplacement doit
|
||||
concerner le SSD NVMe ou la carte mère.
|
||||
|
||||
actions_title: "Prochaines étapes"
|
||||
|
||||
actions:
|
||||
- title: "Sauvegarder les données"
|
||||
status: "priority"
|
||||
text: >
|
||||
Sécuriser les données importantes avant de poursuivre les essais.
|
||||
|
||||
- title: "Tester le SSD et le port M.2"
|
||||
status: "pending"
|
||||
text: >
|
||||
Tester le SSD dans un autre environnement et, si possible, un SSD connu
|
||||
comme fonctionnel dans ce poste. Ce test doit permettre de départager
|
||||
rapidement le SSD et la carte mère.
|
||||
|
||||
- title: "Escalade constructeur"
|
||||
status: "recommended"
|
||||
text: >
|
||||
Préparer une intervention constructeur si les essais mettent en cause
|
||||
le port M.2, la plateforme PCIe ou la carte mère.
|
||||
|
||||
closing: >
|
||||
L'origine matérielle est désormais l'hypothèse principale. Le prochain point
|
||||
de décision est simple : déterminer par test croisé si la panne suit le SSD
|
||||
NVMe ou reste avec le poste. Ce résultat déterminera si la suite consiste
|
||||
principalement à remplacer le SSD ou à escalader vers une intervention sur
|
||||
la carte mère.
|
||||
|
|
@ -0,0 +1,285 @@
|
|||
id: "BEF-2026-09-15-MANUFACTURER-001"
|
||||
|
||||
organization: "Beffroi"
|
||||
|
||||
title: "System Stability Investigation — Technical Report"
|
||||
subtitle: "Recurring system freezes and storage / PCIe device errors"
|
||||
|
||||
report_type: "technical"
|
||||
theme: "default"
|
||||
|
||||
status: "open"
|
||||
severity: "high"
|
||||
|
||||
metadata:
|
||||
Date: "2026-09-15"
|
||||
Device: "DESKTOP-SAU019H"
|
||||
Manufacturer: "PC Specialist / Clevo"
|
||||
Model: "NH5x_NH7x_HHx_HJx_HKx"
|
||||
Motherboard: "CLEVO NHxxHJHK"
|
||||
BIOS: "Insyde 1.07.07TPCS1 — 2021-09-16"
|
||||
OS: "Windows 11 Pro"
|
||||
CPU: "Intel Core i7-11800H"
|
||||
Memory: "16 GB"
|
||||
Graphics: "Intel UHD Graphics + NVIDIA GeForce GTX 1650"
|
||||
SystemDrive: "128GB PCS 2.5\" SATA SSD"
|
||||
SecondaryStorage: "1TB PCS PCIe M.2 SSD"
|
||||
Wireless: "Intel Wi-Fi 6 AX200 160MHz"
|
||||
Author: "Maximilien Rigaut"
|
||||
Purpose: "Manufacturer technical escalation"
|
||||
|
||||
summary: >
|
||||
The system is experiencing recurring hard freezes requiring forced shutdown.
|
||||
Investigation has identified a persistent history of NVMe controller resets
|
||||
and controller errors associated with \Device\RaidPort2.
|
||||
|
||||
The issue remains present after Windows component and system-file repairs,
|
||||
after verification of Windows integrity, and with Fast Startup disabled.
|
||||
|
||||
During the most recent hard freeze on 2026-09-15, the Intel Wi-Fi 6 AX200
|
||||
simultaneously entered a severe device/driver failure sequence while another
|
||||
NVMe controller error was recorded. Review of historical logs identified
|
||||
comparable NVMe and AX200 failure clusters on previous dates.
|
||||
|
||||
The available evidence therefore indicates a persistent hardware or
|
||||
platform-level issue involving the NVMe / PCIe path. The collected evidence
|
||||
does not establish which individual component is responsible.
|
||||
|
||||
timeline:
|
||||
- time: "March 2026"
|
||||
event: "Historical NVMe errors identified"
|
||||
notes: >
|
||||
System event logs contain repeated stornvme Event 129 device resets and
|
||||
Event 11 controller errors against \Device\RaidPort2.
|
||||
|
||||
- time: "2026-03-19"
|
||||
event: "NVMe and wireless failure cluster"
|
||||
notes: >
|
||||
RaidPort2 reset/controller errors and an Intel AX200 failure sequence
|
||||
occurred within the same short time interval. AX200 events included an
|
||||
internal failure, TX/CMD timeout, adapter-not-functioning reports and
|
||||
miniport reset watchdog activity.
|
||||
|
||||
- time: "2026-06-08"
|
||||
event: "Second NVMe and wireless failure cluster"
|
||||
notes: >
|
||||
Multiple RaidPort2 resets and controller errors occurred in close
|
||||
proximity to another Intel AX200 TX/CMD timeout and reset sequence.
|
||||
|
||||
- time: "June 2026"
|
||||
event: "Additional NVMe errors"
|
||||
notes: >
|
||||
Further RaidPort2 reset/controller errors were recorded independently of
|
||||
the identified wireless failure clusters.
|
||||
|
||||
- time: "2026-09-04"
|
||||
event: "Recurring system freezes"
|
||||
notes: >
|
||||
Multiple hard freezes were observed. The system subsequently failed to
|
||||
complete a normal shutdown and required a forced power-off.
|
||||
|
||||
- time: "2026-09-04"
|
||||
event: "Storage errors around incident period"
|
||||
notes: >
|
||||
Repeated stornvme Event 129 resets and Event 11 controller errors against
|
||||
\Device\RaidPort2 were present in the System event log.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Windows repair completed"
|
||||
notes: >
|
||||
DISM /Online /Cleanup-Image /RestoreHealth completed successfully.
|
||||
SFC subsequently detected and repaired protected system files.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Windows integrity verified"
|
||||
notes: >
|
||||
Following restart, a subsequent SFC scan completed with no integrity
|
||||
violations detected.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Fast Startup disabled"
|
||||
notes: >
|
||||
Hibernation and Fast Startup were disabled using powercfg /h off to remove
|
||||
the previously observed Fast Startup failure path from further testing.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "NVMe enumeration investigated"
|
||||
notes: >
|
||||
Windows PnP enumerated both the Standard NVM Express Controller and the
|
||||
associated 1TB PCS PCIe M.2 SSD. The controller reported normal PnP
|
||||
status and an active PCIe Gen3 x4 link.
|
||||
|
||||
- time: "2026-09-14"
|
||||
event: "Storage-stack enumeration discrepancy"
|
||||
notes: >
|
||||
Despite successful PnP enumeration, Get-Disk and Get-PhysicalDisk exposed
|
||||
only the 128GB PCS SATA SSD. The 1TB NVMe SSD was not exposed as a normal
|
||||
usable disk through the Windows storage stack.
|
||||
|
||||
- time: "2026-09-14 16:23:21"
|
||||
event: "NVMe controller error after Windows repair"
|
||||
notes: >
|
||||
stornvme Event 11 reported a controller error on \Device\RaidPort2 after
|
||||
the Windows repair and integrity checks had been completed.
|
||||
|
||||
- time: "2026-09-15 08:55-08:58"
|
||||
event: "NVMe errors before latest freeze"
|
||||
notes: >
|
||||
stornvme recorded two Event 129 resets against \Device\RaidPort2 followed
|
||||
by Event 11 reporting a controller error.
|
||||
|
||||
- time: "2026-09-15 ~09:18"
|
||||
event: "Hard system freeze"
|
||||
notes: >
|
||||
The system became unresponsive. The touchpad stopped responding first,
|
||||
followed by a complete system freeze.
|
||||
|
||||
- time: "2026-09-15 09:19:52"
|
||||
event: "Intel AX200 failure sequence"
|
||||
notes: >
|
||||
Netwtw10 recorded an internal adapter failure and TX/CMD timeout
|
||||
(TfdQueue hanged). Further events reported that the adapter was not
|
||||
functioning properly.
|
||||
|
||||
- time: "2026-09-15 09:19:56"
|
||||
event: "Concurrent NVMe controller error"
|
||||
notes: >
|
||||
stornvme Event 11 reported a controller error on \Device\RaidPort2 while
|
||||
the AX200 failure sequence was ongoing.
|
||||
|
||||
- time: "2026-09-15 09:19:56-09:19:57"
|
||||
event: "Wireless failure continues"
|
||||
notes: >
|
||||
The AX200 generated repeated invalid-value events followed by Driver
|
||||
Miniport reset watchdog events during recovery.
|
||||
|
||||
findings:
|
||||
- title: "Recurring NVMe controller errors"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
stornvme Event 129 resets and Event 11 controller errors against
|
||||
\Device\RaidPort2 are present repeatedly across March, June and September
|
||||
2026.
|
||||
assessment: >
|
||||
The NVMe/storage-path error is persistent rather than an isolated event.
|
||||
|
||||
- title: "NVMe errors persist after Windows repair"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
DISM and SFC repairs completed successfully and subsequent SFC validation
|
||||
reported no integrity violations. A new stornvme Event 11 was recorded
|
||||
afterwards, followed by further Event 129/11 activity and another hard
|
||||
freeze on September 15.
|
||||
assessment: >
|
||||
The recurring NVMe errors have not been resolved by the completed Windows
|
||||
integrity repairs.
|
||||
|
||||
- title: "1 TB NVMe enumeration discrepancy"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
Windows PnP detects the Standard NVM Express Controller and the
|
||||
1TB PCS PCIe M.2 SSD. The controller reports normal PnP status and an
|
||||
active PCIe Gen3 x4 link. During investigation, however, the 1 TB device
|
||||
was not exposed by Get-Disk or Get-PhysicalDisk.
|
||||
assessment: >
|
||||
The device is detectable at the PCIe/PnP level while not being presented
|
||||
as a normal usable disk by the Windows storage stack.
|
||||
|
||||
- title: "Cross-device errors during hard-freeze incident"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
During the September 15 freeze window, the Intel AX200 reported internal
|
||||
failure, TX/CMD timeout, adapter malfunction and miniport reset watchdog
|
||||
events. stornvme Event 11 was recorded during the same failure sequence.
|
||||
assessment: >
|
||||
More than one device experienced low-level errors during the incident.
|
||||
|
||||
- title: "Historical recurrence of cross-device failure pattern"
|
||||
severity: "high"
|
||||
status: "confirmed"
|
||||
evidence: >
|
||||
Review of historical logs identified similar short-window combinations
|
||||
of NVMe/RaidPort2 errors and Intel AX200 failure/reset events on
|
||||
March 19 and June 8.
|
||||
assessment: >
|
||||
The September 15 cross-device event is not unique in the available
|
||||
history.
|
||||
|
||||
- title: "Windows integrity"
|
||||
severity: "info"
|
||||
status: "verified"
|
||||
evidence: >
|
||||
DISM completed successfully. SFC repaired detected corruption and a
|
||||
subsequent SFC scan after restart reported no integrity violations.
|
||||
assessment: >
|
||||
Windows integrity remediation has been completed and verified.
|
||||
|
||||
sections:
|
||||
- title: "Diagnostic steps completed"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- "Reviewed System event history for storage and device failures."
|
||||
- "Correlated stornvme Event 11 and Event 129 occurrences across multiple months."
|
||||
- "Completed DISM component-store repair."
|
||||
- "Completed SFC system-file repair and post-restart verification."
|
||||
- "Disabled hibernation and Fast Startup for subsequent testing."
|
||||
- "Verified enumeration of the NVMe controller through Windows Plug and Play."
|
||||
- "Verified enumeration of the 1TB PCS PCIe M.2 SSD through Windows Plug and Play."
|
||||
- "Verified the NVMe controller was linked at PCIe Gen3 x4 during inspection."
|
||||
- "Compared PnP enumeration with Get-Disk and Get-PhysicalDisk results."
|
||||
- "Captured event logs immediately surrounding the September 15 hard freeze."
|
||||
- "Reviewed historical logs for previous occurrences of the same NVMe / AX200 error pattern."
|
||||
|
||||
- title: "Current observations"
|
||||
content:
|
||||
- type: bullets
|
||||
items:
|
||||
- "Hard freezes remain reproducible/intermittent."
|
||||
- "NVMe controller resets and controller errors recur over a period of several months."
|
||||
- "The errors continue after Windows integrity repair."
|
||||
- "The 1 TB NVMe is detectable at PnP level but is not consistently exposed as a usable Windows disk."
|
||||
- "The September 15 hard freeze coincided with severe errors affecting both the NVMe path and Intel AX200."
|
||||
- "Comparable cross-device error clusters are present in historical logs."
|
||||
|
||||
- title: "Leading working theory"
|
||||
content:
|
||||
- type: callout
|
||||
title: "Current technical assessment"
|
||||
kind: "warning"
|
||||
text: >
|
||||
The collected evidence is consistent with a persistent hardware or
|
||||
platform-level fault affecting the NVMe / PCIe path. The repeated
|
||||
occurrence of severe errors involving both the NVMe controller and
|
||||
Intel AX200 during some incidents suggests that the fault may not be
|
||||
limited to Windows or to a single software component.
|
||||
|
||||
The available diagnostics do not currently isolate the fault to a
|
||||
specific replaceable component.
|
||||
|
||||
actions_title: "Escalation"
|
||||
|
||||
actions:
|
||||
- title: "Manufacturer review"
|
||||
status: "requested"
|
||||
text: >
|
||||
The system is being escalated for manufacturer review based on recurring
|
||||
hard freezes, persistent NVMe controller errors and repeated cross-device
|
||||
failure events. Detailed and deduplicated event-log extracts can be
|
||||
supplied alongside this report.
|
||||
|
||||
closing: >
|
||||
Software integrity issues identified during the investigation have been
|
||||
repaired and verified, but the original stability problem remains. Persistent
|
||||
NVMe controller errors are documented over several months, and the latest
|
||||
user-observed hard freeze coincided with severe errors affecting both the
|
||||
NVMe storage path and Intel AX200 wireless adapter.
|
||||
|
||||
This report is provided to document the observations and diagnostic work
|
||||
completed to date. Component-level fault isolation and determination of the
|
||||
appropriate hardware remediation are left to the manufacturer's technical
|
||||
assessment.
|
||||
Reference in New Issue