Update reports/2026-09-14-system-stability-diagnostic-notes.yaml
Report CI typst_reporter passed all CI checks.
Beffroi/typst_reporter/pipeline/head This commit looks good Details

This commit is contained in:
Dandaedre 2026-09-14 16:35:23 +02:00
parent 2b73b46cb3
commit f2944ff719
1 changed files with 500 additions and 315 deletions

View File

@ -1,453 +1,638 @@
id: "BEF-2026-09-14-DIAG-001"
id: "BEF-2026-09-14-CLEVO-002"
organization: "Beffroi"
title: "System Stability Investigation — Diagnostic Test Record"
subtitle: "Windows repair, storage, memory, CPU and graphics validation — internal technical notes"
title: "System Stability Investigation — Storage / Firmware Follow-up"
subtitle: "PC Specialist / Clevo — exhaustive diagnostic record and current assessment"
report_type: technical
theme: default
status: "open"
severity: "medium"
severity: "high"
metadata:
Date: "2026-09-14"
Device: "DESKTOP-DH4HOT6"
Platform: "ASUS GA402RJ"
BIOS: "American Megatrends International, LLC. GA402RJ.318 — 2023-03-09"
OS: "Windows 11 Pro — 10.0.26200 / build 26200"
SystemDrive: "Micron_2450_MTFDKBA1T0TFK — 953.87 GiB NVMe SSD"
Graphics: "AMD Radeon(TM) Graphics + AMD Radeon RX 6700S"
GraphicsDriver: "32.0.21045.5002 — 2026-08-17"
Device: "DESKTOP-SAU019H"
Model: "PC Specialist / Clevo NH5x_NH7x_HHx_HJx_HKx"
Motherboard: "CLEVO NHxxHJHK"
BIOS: "Insyde 1.07.07TPCS1 — 2021-09-16"
CPU: "Intel Core i7-11800H"
Memory: "16 GB"
GPU: "Intel UHD Graphics + NVIDIA GeForce GTX 1650"
OS: "Windows 11 Pro — image version 10.0.26200.9168"
SATAStorage: "128GB PCS 2.5-inch SSD — serial U9DI16295T"
NVMeStorage: "1TB PCS PCIe M.2 SSD — Silicon Motion NVMe controller PCI VEN_126F DEV_2263"
Author: "Maximilien Rigaut"
Purpose: "Internal diagnostic notes; not intended as hierarchy-facing incident synthesis"
Purpose: "Continuation and consolidation of the 2026-09-04 Clevo stability investigation"
summary: >
A structured diagnostic session was performed on 2026-09-14 following the
earlier investigation into hard freezes, shutdown anomalies and firmware /
NVRAM-related warnings. Windows component-store corruption and protected
system-file corruption were confirmed and successfully repaired. Subsequent
integrity, filesystem, memory, CPU and initial graphics tests completed
without reproducing a freeze and without producing relevant storage, WHEA or
display-driver errors. The system drive currently reports Healthy / OK and
NTFS reports no filesystem errors or bad sectors. Windows Memory Diagnostic
reported no memory errors. CPU WinSAT and Desktop Window Manager graphics
WinSAT completed normally. A sustained discrete-GPU test has not yet been
performed. The root cause of the historical freezes therefore remains
unproven.
The investigation of DESKTOP-SAU019H was resumed on 2026-09-14 after earlier
hard freezes, shutdown anomalies, an NVRAM-reset firmware warning, TPM /
Measured Boot errors and repeated NVMe controller errors. Fast Startup was
disabled by disabling hibernation. DISM successfully repaired the Windows
component store and SFC found and repaired protected system-file corruption;
a subsequent SFC scan after restart reported no remaining integrity
violations. Storage enumeration before restart exposed only the 128 GB SATA
SSD through Get-Disk and Get-PhysicalDisk, while the 1 TB NVMe remained known
to Plug and Play. After restart, Windows positively enumerated the 1 TB PCS
PCIe M.2 SSD and its Standard NVM Express Controller as present and working
properly, with the controller linked at PCIe Gen3 x4, but Get-Disk still
exposed only the 128 GB SATA SSD. A new stornvme Event 11 occurred at
16:23:21 on 2026-09-14, reporting a controller error on \Device\RaidPort2.
Historical Event 129 resets and Event 11 controller errors against the same
RaidPort2 are present on 2026-09-04 and repeatedly as far back as March 2026.
The BIOS menus inspected during this session did not list the 1 TB NVMe/SATA
device. The strongest current lead is therefore an intermittent or partial
failure somewhere in the 1 TB NVMe storage path: the SSD itself, its M.2
connection, PCIe link / slot, controller behaviour, firmware interaction or
power delivery. A failing SSD is not yet conclusively proven. The NVRAM /
CMOS issue remains a separate open diagnostic track.
timeline:
- time: "12:13"
event: "Baseline system inventory"
- time: "2026-09-04 ~15:21"
event: "NVMe controller error"
notes: >
Windows reported Windows 11 Pro 10.0.26200, build 26200. At this point
LastBootUpTime was 2026-09-04 17:27:40.
stornvme Event 11 reported a controller error on \Device\RaidPort2.
- time: "12:13"
event: "Firmware inventory"
- time: "2026-09-04 ~16:30"
event: "Firmware / NVRAM warning"
notes: >
BIOS identified as American Megatrends International, LLC. GA402RJ.318,
release date 2023-03-09.
Firmware displayed a first-boot or NVRAM-reset-condition warning.
- time: "12:13"
event: "Storage inventory"
- time: "2026-09-04 ~16:32"
event: "TPM / Measured Boot failure"
notes: >
Windows exposed one physical disk: Micron_2450_MTFDKBA1T0TFK, NVMe SSD,
approximately 953.87 GiB usable, HealthStatus Healthy and
OperationalStatus OK.
TPM-WMI Event 1040 reported a critical pre-attestation health-check
failure and referenced a MeasuredBoot diagnostic JSON file.
- time: "~12:15"
event: "Current storage/WHEA event review"
- time: "2026-09-04 ~16:44"
event: "Second confirmed NVMe controller error"
notes: >
No disk, stornvme, Ntfs, volmgr or WHEA-Logger events were returned for
the current boot interval.
stornvme Event 11 again reported a controller error on
\Device\RaidPort2.
- time: "~12:20"
event: "NVMe reliability telemetry review"
- time: "2026-09-04 ~16:53"
event: "Normal shutdown failure"
notes: >
Get-StorageReliabilityCounter reported temperature 47 C, historical
maximum 83 C, wear 0, maximum read latency 550 ms, maximum write latency
861 ms. Windows did not expose read/write error counters or power-on
hours for this device.
Windows shutdown hung and a forced power-off was required.
- time: "~12:25"
- time: "2026-09-04 later"
event: "Restart test"
notes: >
A normal Windows restart completed successfully.
- time: "2026-09-04 later"
event: "Full-shutdown test bypassing Fast Startup"
notes: >
A full shutdown completed normally when Fast Startup was bypassed.
- time: "2026-09-04 <17:23"
event: "Hard freeze"
notes: >
A system freeze occurred before further configuration changes.
- time: "2026-09-04 ~17:25"
event: "Second hard freeze"
notes: >
A second freeze / hang was observed.
- time: "2026-09-14 before storage retest"
event: "Fast Startup disabled"
notes: >
powercfg /h off completed without error. Hibernation was disabled,
which also disables Windows Fast Startup.
- time: "2026-09-14 before storage retest"
event: "DISM CheckHealth syntax attempt"
notes: >
DISM /CheckHealth returned Error 87 because /Online /Cleanup-Image
were omitted. This was a command syntax issue and not a diagnostic
failure.
- time: "2026-09-14 before storage retest"
event: "DISM component-store repair"
notes: >
DISM /Online /Cleanup-Image /RestoreHealth completed at 100 percent with
"The restore operation completed successfully" and "The operation
completed successfully."
DISM /Online /Cleanup-Image /RestoreHealth completed at 100 percent.
DISM reported that the restore operation and overall operation
completed successfully.
- time: "~12:29"
event: "SFC repair"
- time: "2026-09-14 before storage retest"
event: "SFC system-file repair"
notes: >
sfc /scannow reported that Windows Resource Protection found corrupt
files and successfully repaired them.
sfc /scannow found corrupt files and successfully repaired them.
- time: "12:30"
event: "Controlled restart"
- time: "2026-09-14 before restart"
event: "Initial disk inventory"
notes: >
System restarted normally. Windows subsequently reported
LastBootUpTime 2026-09-14 12:30:11.
Get-Disk exposed only Disk 0, the 128GB PCS 2.5-inch SATA SSD,
Online and Healthy. The 1 TB NVMe was absent from Get-Disk.
- time: "~12:31"
event: "Post-repair event review"
- time: "2026-09-14 before restart"
event: "Initial physical-disk inventory"
notes: >
Only DistributedCOM Event 10016 warnings and two Kernel-PnP Event 219
WUDFRd warnings were observed in the supplied boot-time event output.
No disk, NVMe, NTFS, WHEA or Kernel-Power failure was observed in that
output.
Get-PhysicalDisk exposed only the 128GB PCS 2.5-inch SATA SSD,
Healthy / OK. The 1 TB NVMe was absent from this storage-provider view.
- time: "~12:32"
- time: "2026-09-14 before restart"
event: "PnP controller inventory"
notes: >
A Standard NVM Express Controller with hardware ID PCI\VEN_126F&DEV_2263
existed in Plug and Play history but was initially shown with status
Unknown in the non-PresentOnly query.
- time: "2026-09-14 before restart"
event: "PnP disk inventory"
notes: >
A 1TB PCS PCIe M.2 SSD device entry existed in Plug and Play history
but was initially shown with status Unknown in the non-PresentOnly
query. Numerous historical USB storage entries were also present,
demonstrating that this query included devices not currently attached.
- time: "2026-09-14 before restart"
event: "SATA reliability telemetry"
notes: >
Get-StorageReliabilityCounter returned data for DeviceId 0, the visible
128 GB SATA SSD: 2033 power-on hours, 40 C temperature, wear 0,
ReadErrorsTotal 0, ReadErrorsUncorrected 0, maximum read latency
4253 ms and maximum write latency 6122 ms. This telemetry did not
describe the 1 TB NVMe.
- time: "2026-09-14 restart / BIOS inspection"
event: "BIOS storage inspection"
notes: >
The BIOS menus inspected by the operator did not show a 1 TB NVMe or
SATA storage device. This observation is retained as evidence, but the
exact Clevo/Insyde BIOS menu capabilities have not been established;
absence from a BIOS menu does not by itself prove failure to enumerate
the PCIe function.
- time: "2026-09-14 16:15:38"
event: "NVMe controller arrival after reboot"
notes: >
Windows recorded the Standard NVM Express Controller LastArrivalDate
as 2026-09-14 16:15:38.
- time: "2026-09-14 ~16:15 onward"
event: "PresentOnly controller enumeration"
notes: >
Get-PnpDevice -PresentOnly positively enumerated the Standard NVM
Express Controller as present with Status OK.
- time: "2026-09-14 ~16:15 onward"
event: "PresentOnly 1 TB NVMe disk enumeration"
notes: >
Get-PnpDevice -PresentOnly -Class DiskDrive positively enumerated
1TB PCS PCIe M.2 SSD with Status OK alongside the 128 GB SATA SSD.
- time: "2026-09-14 ~16:15 onward"
event: "Get-Disk still omitted NVMe"
notes: >
Despite positive current PnP enumeration of the NVMe controller and
disk device, Get-Disk still exposed only the 128 GB SATA SSD.
- time: "2026-09-14 ~16:15 onward"
event: "NVMe controller state inspected"
notes: >
The controller reported CM_PROB_NONE, ConfigManagerErrorCode
CM_PROB_NONE, Status OK, Present True, HasProblem False and service
stornvme.
- time: "2026-09-14 ~16:15 onward"
event: "NVMe PCIe link inspected"
notes: >
Device properties reported PCI bus 2, device 0, function 0,
CurrentLinkSpeed 3, CurrentLinkWidth 4, MaxLinkSpeed 3 and
MaxLinkWidth 4. The controller was therefore actively enumerated on a
PCIe Gen3 x4 link at the time of inspection.
- time: "2026-09-14 16:23:21"
event: "New NVMe controller error"
notes: >
stornvme Event 11 reported: "The driver detected a controller error on
\Device\RaidPort2." This event occurred during the current diagnostic
session after the NVMe controller had arrived and been enumerated.
- time: "2026-09-14 after 16:23"
event: "Historical stornvme event review"
notes: >
Event-log review confirmed repeated Event 129 device resets and
Event 11 controller errors on \Device\RaidPort2 on 2026-09-04 and
repeatedly in June and March 2026. The pattern therefore predates the
September incident.
- time: "2026-09-14 after event review"
event: "Post-repair SFC verification"
notes: >
sfc /verifyonly completed successfully and reported no integrity
violations.
- time: "~12:35"
event: "Online NTFS scan"
notes: >
chkdsk C: /scan completed successfully. Windows reported no filesystem
problems, no further action required, 0 bad file records and 0 KB in bad
sectors.
- time: "13:08"
event: "Windows Memory Diagnostic result"
notes: >
Microsoft-Windows-MemoryDiagnostics-Results Events 1201 and 1101 both
reported that the computer's memory was tested and no errors were
detected.
- time: "13:21-13:23"
event: "CPU WinSAT assessment"
notes: >
winsat cpuformal completed normally in approximately 81.76 seconds.
No crash, freeze or relevant system event was observed during or
immediately following the assessment.
- time: "~13:25"
event: "Graphics inventory"
notes: >
Windows reported AMD Radeon(TM) Graphics and AMD Radeon RX 6700S, both
with Status OK and driver version 32.0.21045.5002 dated 2026-08-17.
Both display devices also reported PnP status OK.
- time: "~13:25"
event: "Recent graphics event review"
notes: >
No Display, amdwddmg or nvlddmkm provider events were returned from the
previous 14 days by the supplied query.
- time: "13:26-13:27"
event: "Desktop graphics WinSAT assessment"
notes: >
winsat dwmformal completed normally. Desktop graphics performance test
ran for approximately 10.47 seconds and reported video memory throughput
of 23540.20 MB/s. No relevant display or AMD event followed the test.
- time: "13:27"
event: "Attempted WinSAT D3D assessment"
notes: >
winsat d3dformal did not execute because the assessment name is not valid
on the installed Windows version. This is recorded as a test-command
limitation, not a system failure.
A second sfc /scannow completed with "Windows Resource Protection did
not find any integrity violations."
findings:
- title: "Fast Startup disabled for diagnosis"
severity: "info"
status: "completed"
evidence: >
powercfg /h off completed successfully.
assessment: >
Disabling hibernation disables Windows Fast Startup and removes the
previously observed Fast Startup path from subsequent shutdown and boot
tests. This is an appropriate diagnostic control and should remain in
place until the investigation is complete.
- title: "Windows component-store corruption"
severity: "medium"
status: "repaired"
evidence: >
The previously identified repairable component store was repaired with
DISM /Online /Cleanup-Image /RestoreHealth. DISM completed successfully.
DISM /Online /Cleanup-Image /RestoreHealth completed successfully.
assessment: >
This was a genuine Windows integrity issue. It is now repaired. It may
have contributed to instability, but the available evidence does not
establish whether it caused the historical hard freezes or resulted from
previous forced shutdowns.
A Windows integrity problem existed and was repaired. The evidence does
not establish whether corruption contributed to the hard freezes,
resulted from forced power-offs, or was unrelated.
- title: "Protected Windows system-file corruption"
severity: "medium"
status: "repaired"
evidence: >
Following DISM, sfc /scannow found corrupt files and successfully
repaired them. After restart, sfc /verifyonly reported no integrity
violations.
The first sfc /scannow found corrupt files and repaired them. A later
sfc /scannow after restart reported no integrity violations.
assessment: >
The repair has been validated after reboot. Windows system-file integrity
is currently clean.
Windows protected-file integrity is currently clean. Recurrent immediate
corruption was not observed after repair and reboot.
- title: "System NVMe device health"
severity: "info"
status: "currently-normal"
- title: "1 TB NVMe absent from Get-Disk / Get-PhysicalDisk"
severity: "high"
status: "confirmed"
evidence: >
Micron_2450_MTFDKBA1T0TFK reports HealthStatus Healthy and
OperationalStatus OK. Reliability telemetry reports wear 0, current
temperature 47 C and historical maximum temperature 83 C. No current
boot-session disk, stornvme, Ntfs, volmgr or WHEA-Logger events were
returned by the supplied query.
Before restart, both Get-Disk and Get-PhysicalDisk exposed only the
128 GB PCS SATA SSD. After restart, Get-Disk still exposed only the
SATA SSD even though PresentOnly PnP enumeration showed the NVMe
controller and 1 TB NVMe disk as currently present.
assessment: >
There is currently no direct evidence of an actively failing system NVMe
device. The historical maximum temperature is worth retaining in the
record but does not by itself demonstrate failure.
Windows can enumerate the PCIe NVMe function and child disk device but
does not currently expose the 1 TB NVMe as a normal usable disk through
the storage-management layer. This strongly supports a problem in the
NVMe storage path rather than a simple stale Device Manager entry.
- title: "Historical storage errors require device attribution"
severity: "medium"
status: "open"
- title: "1 TB NVMe positively present on PCIe after reboot"
severity: "high"
status: "confirmed"
evidence: >
Historical logs reviewed during this session contain disk Event 51
paging errors, disk Event 11 controller errors and NTFS Event 50 delayed
write failures against \Device\Harddisk1\DRx paths. The currently
enumerated internal Micron system drive is Disk 0 and only one physical
disk is presently visible.
Get-PnpDevice -PresentOnly reported the Standard NVM Express Controller
and 1TB PCS PCIe M.2 SSD as present with Status OK. The controller
reported Present True, HasProblem False, CM_PROB_NONE and a PCIe Gen3
x4 link.
assessment: >
Historical Harddisk1 errors must not be automatically attributed to the
current Micron NVMe. They may have involved a second, removable or
external storage device. Device attribution remains unresolved.
The controller was physically enumerated at the PCIe level during the
session. Therefore the device was not simply absent from the PCIe bus at
the moment these properties were queried. This does not demonstrate
reliable access to the NVMe media.
- title: "NTFS filesystem integrity"
severity: "info"
status: "confirmed-clean"
- title: "Current-session stornvme controller error"
severity: "high"
status: "confirmed"
evidence: >
chkdsk C: /scan found no problems. It reported 0 bad file records and
0 KB in bad sectors, with no further action required.
stornvme Event 11 occurred at 2026-09-14 16:23:21 and reported a
controller error on \Device\RaidPort2.
assessment: >
No offline CHKDSK repair or sector scan is presently justified by the
available filesystem evidence.
This is direct evidence of an active storage-controller/path failure
during the current session. It materially raises the priority of the
1 TB NVMe path as a potential explanation for the historical freezes.
- title: "System memory"
severity: "info"
status: "test-passed"
- title: "Long-running RaidPort2 reset / error pattern"
severity: "high"
status: "confirmed"
evidence: >
Windows Memory Diagnostic completed and Events 1201 and 1101 both state
that the computer's memory was tested and no errors were detected.
Historical logs contain repeated stornvme Event 129 resets and Event 11
controller errors on \Device\RaidPort2 on 2026-09-04 and repeatedly in
June and March 2026.
assessment: >
No memory fault was detected by the Windows diagnostic. This lowers the
priority of RAM as an explanation for the freezes, while not excluding
rare or workload-specific intermittent faults.
The storage-path problem is recurrent and predates the September 2026
hard-freeze investigation. This makes a one-off Windows corruption event
an insufficient explanation for the controller-error history.
- title: "CPU stability under WinSAT workload"
severity: "info"
status: "test-passed"
evidence: >
winsat cpuformal completed all CPU compression, encryption and hashing
assessments in approximately 81.76 seconds without freeze, restart or
relevant error event.
assessment: >
No CPU instability was reproduced by this short controlled workload.
This is not equivalent to a long-duration thermal or power stress test.
- title: "Graphics device enumeration and initial graphics test"
severity: "info"
status: "initial-test-passed"
evidence: >
AMD Radeon(TM) Graphics and AMD Radeon RX 6700S both report status OK.
Both use AMD driver 32.0.21045.5002 dated 2026-08-17. winsat dwmformal
completed successfully with 23540.20 MB/s video-memory throughput and no
relevant display/AMD event observed afterward.
assessment: >
Basic desktop graphics acceleration is functioning. This test is too
short and too light to clear the discrete GPU, graphics power delivery,
thermals or hybrid-GPU transitions as possible intermittent causes.
- title: "Background DCOM warnings"
severity: "info"
status: "observed"
evidence: >
Repeated Microsoft-Windows-DistributedCOM Event 10016 warnings were
present after restart and during later testing.
assessment: >
These warnings are retained for traceability but are not currently
considered explanatory for the hard-freeze symptom.
- title: "Kernel-PnP WUDFRd warnings"
severity: "low"
status: "observed"
evidence: >
Two Kernel-PnP Event 219 warnings were observed immediately after the
controlled restart, including HID\VID_0B05&PID_19B6&MI_01 and
ROOT\WINDOWSHELLOFACESOFTWAREDRIVER\0000, both with status 0xC0000365.
assessment: >
No direct link to the freeze has been established. Retain for comparison
if future freezes correlate with device initialization or power-state
transitions.
- title: "Machine identity discrepancy with September 4 reports"
- title: "NVMe physical failure not yet proven"
severity: "high"
status: "open"
evidence: >
The reports currently stored for the 2026-09-04 investigation identify
DESKTOP-SAU019H, PC Specialist / Clevo hardware, Insyde firmware and an
Intel/NVIDIA configuration. The device tested on 2026-09-14 identifies
as DESKTOP-DH4HOT6 with ASUS GA402RJ firmware, AMD integrated graphics
and AMD Radeon RX 6700S.
The NVMe controller and child disk can currently enumerate on PCIe and
report PnP Status OK, while stornvme simultaneously records controller
errors and the disk remains absent from Get-Disk.
assessment: >
These records cannot safely be treated as one hardware inventory without
reconciliation. Either the September 14 session is being performed on a
different affected machine, the earlier reports contain mixed-machine
data, or the investigation thread has combined separate incidents. This
discrepancy should be resolved before using historical device-specific
conclusions such as RaidPort2, Clevo BIOS or Intel/NVIDIA observations
to guide remediation on the current ASUS system.
The evidence is compatible with a failing NVMe SSD, but does not yet
distinguish the SSD itself from the M.2 connection, motherboard slot /
PCIe path, controller firmware, system firmware interaction or power
delivery. The drive should not yet be condemned solely from Event 11.
- title: "BIOS does not list 1 TB storage device in inspected menus"
severity: "medium"
status: "observed"
evidence: >
During the 2026-09-14 BIOS inspection, no 1 TB NVMe/SATA device was
visible to the operator.
assessment: >
Retain this as an important observation. However, the available evidence
does not establish whether this specific Insyde BIOS exposes NVMe device
inventory in its UI. Windows later demonstrated active PCIe enumeration,
so absence from the visible BIOS menus must not be treated as conclusive
proof that firmware failed to enumerate the controller.
- title: "NVRAM / CMOS retention issue"
severity: "high"
status: "open"
evidence: >
The original firmware warning reported a first-boot or NVRAM-reset
condition.
assessment: >
The warning remains unexplained. A failed RTC/CMOS battery is possible
but not proven. A controlled unpowered retention test of BIOS time and
settings remains required. This issue should remain diagnostically
separate from the NVMe fault unless further evidence connects them.
- title: "TPM / Measured Boot pre-attestation failure"
severity: "medium"
status: "open"
evidence: >
TPM-WMI Event 1040 previously reported a critical pre-attestation
health-check failure and referenced a MeasuredBoot JSON diagnostic file.
assessment: >
The temporal association with the NVRAM warning makes a firmware-state
relationship plausible, but no causal relationship has been proven.
The TPM should not be cleared merely as a diagnostic experiment.
- title: "128 GB SATA SSD telemetry"
severity: "info"
status: "currently-normal"
evidence: >
The visible SATA SSD reported Healthy / OK, 40 C, wear 0,
ReadErrorsTotal 0 and ReadErrorsUncorrected 0 in the supplied reliability
counter output.
assessment: >
No direct read-error evidence was observed for the 128 GB SATA SSD in
this checkpoint. The unusually high recorded maximum latency values are
retained for completeness but are not by themselves sufficient to
diagnose failure.
sections:
- title: "Commands and results — boot / shutdown control"
content:
- type: bullets
items:
- >
powercfg /h off — completed without error; hibernation and Fast
Startup disabled.
- >
Previous full-shutdown test bypassing Fast Startup — completed
normally.
- >
Previous normal restart test — completed normally.
- title: "Commands and results — Windows integrity"
content:
- type: bullets
items:
- >
DISM /Online /Cleanup-Image /RestoreHealth — completed at 100%;
restore operation completed successfully.
DISM /CheckHealth — returned Error 87 because the required
/Online /Cleanup-Image arguments were omitted. This result has no
diagnostic significance for Windows health.
- >
sfc /scannow — found corrupt files and successfully repaired them.
DISM /Online /Cleanup-Image /RestoreHealth — reached 100 percent
and completed successfully.
- >
Controlled restart — successful; new boot time
2026-09-14 12:30:11.
First sfc /scannow — found corrupt files and successfully
repaired them.
- >
sfc /verifyonly after restart — no integrity violations.
Second sfc /scannow after restart — no integrity violations found.
- title: "Commands and results — storage"
- title: "Commands and results — initial storage inventory"
content:
- type: bullets
items:
- >
Get-PhysicalDisk / Get-Disk — one Micron 2450 1 TB-class NVMe
device, Healthy / OK.
Get-Disk — only Disk 0, 128GB PCS 2.5-inch SSD, SATA, Online,
Healthy, 128035676160 bytes.
- >
Get-StorageReliabilityCounter — 47 C current, 83 C maximum,
wear 0, read latency max 550 ms, write latency max 861 ms.
Get-PhysicalDisk — only 128GB PCS 2.5-inch SSD, SSD/SATA,
Healthy / OK, 128035676160 bytes.
- >
Current-boot event review — no disk, stornvme, Ntfs, volmgr or
WHEA-Logger events returned.
Get-PnpDevice -Class SCSIAdapter — historical list included a
Standard NVM Express Controller with PCI VEN_126F DEV_2263,
initially shown as Unknown without -PresentOnly.
- >
chkdsk C: /scan — no filesystem problems, 0 KB bad sectors,
no further action required.
Get-PnpDevice -Class DiskDrive — historical list included
1TB PCS PCIe M.2 SSD, initially shown as Unknown without
-PresentOnly, along with many disconnected historical USB devices.
- >
Get-StorageReliabilityCounter — returned telemetry only for the
visible DeviceId 0 / 128 GB SATA SSD: 2033 power-on hours, 40 C,
wear 0, no reported read errors.
- title: "Commands and results — memory"
- title: "Commands and results — post-reboot NVMe enumeration"
content:
- type: bullets
items:
- >
Windows Memory Diagnostic — completed successfully.
Get-PnpDevice -PresentOnly -Class SCSIAdapter — Standard NVM
Express Controller present, Status OK.
- >
Event 1201 — memory tested; no errors detected.
Get-PnpDevice -PresentOnly -Class DiskDrive — 1TB PCS PCIe M.2 SSD
present, Status OK; 128GB PCS 2.5-inch SSD also present.
- >
Event 1101 — memory tested; no errors detected.
Get-Disk — still exposed only the 128 GB SATA SSD.
- >
PresentOnly PCI VEN_126F DEV_2263 query — controller Status OK,
class SCSIAdapter.
- >
Controller detailed properties — CM_PROB_NONE,
ConfigManagerErrorCode CM_PROB_NONE, Present True,
HasProblem False, Service stornvme.
- >
Controller PCI properties — bus 2, device 0, function 0;
current and maximum link speed 3; current and maximum link width 4;
AER capability present.
- >
Controller LastArrivalDate — 2026-09-14 16:15:38.
- >
Controller bus relation and child relationship both reference
SCSI\Disk&Ven_NVMe&Prod_1TB_PCS_PCIe_M.2.
- title: "Commands and results — CPU"
- title: "Commands and results — storage event history"
content:
- type: bullets
items:
- >
winsat cpuformal — completed normally in 00:01:21.76.
2026-09-14 16:23:21 — stornvme Event 11:
controller error on \Device\RaidPort2.
- >
Representative results: CPU LZW 1171.05 MB/s; AES256
15944.45 MB/s; Vista compression 3029.33 MB/s; SHA1
10319.55 MB/s.
2026-09-04 17:22:40 — stornvme Event 11:
controller error on \Device\RaidPort2.
- >
No hardware, WHEA, storage or driver failure was observed in the
supplied event review following the test.
2026-09-04 17:20:46 — stornvme Event 129:
reset to \Device\RaidPort2 issued.
- >
2026-09-04 17:12:39 — stornvme Event 129:
reset to \Device\RaidPort2 issued.
- >
2026-09-04 16:57:14 — stornvme Event 11:
controller error on \Device\RaidPort2.
- >
2026-09-04 16:55:20 — stornvme Event 129:
reset to \Device\RaidPort2 issued.
- >
2026-09-04 16:44:57 — stornvme Event 11:
controller error on \Device\RaidPort2.
- >
2026-09-04 16:43:03 — stornvme Event 129:
reset to \Device\RaidPort2 issued.
- >
2026-09-04 15:21:28 — stornvme Event 11:
controller error on \Device\RaidPort2.
- >
2026-09-04 15:19:32 — stornvme Event 129:
reset to \Device\RaidPort2 issued.
- >
Additional Event 11 / Event 129 occurrences were confirmed on
2026-06-09, 2026-06-08, 2026-03-26, 2026-03-21, 2026-03-20,
2026-03-19 and 2026-03-18.
- title: "Commands and results — graphics"
- title: "BIOS / firmware observations"
content:
- type: bullets
items:
- >
Win32_VideoController — AMD Radeon(TM) Graphics and AMD Radeon
RX 6700S, both Status OK.
Earlier investigation observed: "A first boot or NVRAM reset
condition has been detected."
- >
Get-PnpDevice -Class Display — both display devices Status OK.
BIOS used during this investigation: Insyde 1.07.07TPCS1.
- >
Driver version for both adapters: 32.0.21045.5002 dated
2026-08-17.
Operator inspection on 2026-09-14 found no visible 1 TB NVMe/SATA
device in the BIOS menus examined.
- >
Fourteen-day display-provider query returned no Display,
amdwddmg or nvlddmkm events.
No BIOS update or firmware flash has been performed during this
diagnostic sequence.
- >
winsat dwmformal — completed successfully; video memory
throughput 23540.20 MB/s.
- >
winsat d3dformal — invalid assessment name on this Windows
installation; no test was performed.
No TPM clear has been performed.
- title: "Interpretation at this checkpoint"
content:
- type: callout
title: "Current state"
kind: "info"
kind: "warning"
text: >
The system has not frozen during the controlled 2026-09-14 test
sequence. Windows corruption was real and has been repaired, but
there is presently insufficient evidence to conclude that it was the
sole root cause of the historical freezes.
Windows software integrity has been repaired and verified clean, but
the storage problem remains active. The 1 TB NVMe controller and
child disk can enumerate on PCIe while the disk remains absent from
Get-Disk, and a new Event 11 controller error was generated during
the current session. This substantially strengthens the NVMe /
M.2 / PCIe storage-path hypothesis for the hard-freeze investigation.
It still does not identify which physical component in that path is
defective.
- type: bullets
items:
- "No active storage failure has been demonstrated."
- "No filesystem corruption remains after repair."
- "No memory fault was detected by Windows Memory Diagnostic."
- "No CPU instability was reproduced by WinSAT."
- "Initial graphics acceleration testing passed."
- "A sustained discrete-GPU workload has not yet been performed."
- "Combined CPU/GPU thermal and power-load testing has not yet been performed."
- "Firmware/NVRAM retention testing remains outstanding."
- "Historical TPM / Measured Boot findings have not yet been revalidated on this specific hardware identity."
- "Fast Startup is disabled and should remain disabled during diagnosis."
- "Windows component-store corruption has been repaired."
- "Windows protected system files are currently clean."
- "The 128 GB SATA SSD is the only disk exposed by Get-Disk."
- "The 1 TB NVMe controller is currently enumerated on PCIe Gen3 x4."
- "The 1 TB NVMe child disk is currently visible to PresentOnly PnP."
- "The 1 TB NVMe is nevertheless absent from Get-Disk."
- "A new stornvme Event 11 occurred during this diagnostic session."
- "RaidPort2 Event 11 / 129 faults recur over several months."
- "The 1 TB SSD itself is a primary suspect but is not yet conclusively proven defective."
- "M.2 seating, slot / motherboard path and power delivery remain plausible alternatives."
- "The NVRAM / CMOS issue remains open and should not yet be merged with the NVMe diagnosis."
- "TPM / Measured Boot evidence remains preserved and unresolved."
- "A BIOS flash is not currently justified as a first remediation step."
actions_title: "Recommended continuation"
actions_title: "Recommended next diagnostic steps"
actions:
- title: "Reconcile machine identity"
status: "pending"
- title: "Back up important data"
status: "priority"
text: >
Confirm whether DESKTOP-DH4HOT6 / ASUS GA402RJ is the same intended
incident target as the 2026-09-04 reports describing DESKTOP-SAU019H /
PC Specialist-Clevo. If separate machines are involved, separate their
diagnostic records and avoid carrying device-specific conclusions
between them.
Ensure all important data is backed up before further manipulation or
testing. Recurrent NVMe controller resets/errors justify treating the
storage path as potentially unreliable.
- title: "Perform sustained discrete-GPU test"
- title: "Perform controlled full shutdown"
status: "pending"
text: >
Exercise the Radeon RX 6700S under a controlled sustained 3D workload
while connected to the normal AC adapter and using the normal power /
GPU profile. Record start and end timestamps, temperatures if available,
and any freeze, artifact, driver reset, black screen or unexpected
restart.
With Fast Startup already disabled, perform a full shutdown before any
physical inspection.
commands:
- "shutdown /s /t 0"
- title: "Review events after GPU workload"
- title: "Physically inspect and reseat the 1 TB M.2 NVMe"
status: "pending"
text: >
Inspect System and Application logs immediately after the GPU test for
Display, AMD, amdwddmg, WHEA-Logger, Kernel-Power and related events.
Disconnect AC power and, where service procedure permits, disconnect
the internal battery before handling the M.2 drive. Photograph the SSD
label and exact part number. Inspect the retaining screw, seating,
contacts and socket; remove and firmly reseat the SSD. Do not change
unrelated firmware settings during the same test.
- title: "Perform combined power and thermal test"
- title: "Retest storage enumeration after reseat"
status: "pending"
text: >
If the discrete-GPU test is stable, proceed to a controlled combined
CPU/GPU workload. The purpose is to exercise cooling, platform power
delivery and shared thermal limits rather than benchmark performance.
After reseating, boot the machine and determine whether the 1 TB NVMe
becomes a normal disk and whether new stornvme errors appear.
commands:
- "Get-Disk"
- "Get-PhysicalDisk"
- "Get-PnpDevice -PresentOnly -Class SCSIAdapter"
- "Get-PnpDevice -PresentOnly -Class DiskDrive"
- title: "Test firmware/NVRAM retention"
- title: "Review post-reseat stornvme events"
status: "pending"
text: >
Record BIOS date/time and relevant settings, perform a complete shutdown
and unpowered interval, then verify that firmware state remains intact.
Record whether the previous NVRAM warning recurs.
Check the System log for fresh Event 11 or Event 129 entries immediately
after the test boot.
commands:
- "Get-WinEvent -FilterHashtable @{ LogName='System'; ProviderName='stornvme'; StartTime=(Get-Date).AddMinutes(-30) } | Format-List TimeCreated, Id, LevelDisplayName, Message"
- title: "Correlate any future freeze"
- title: "Isolate SSD versus motherboard path if errors persist"
status: "pending"
text: >
If another hard freeze occurs, record the exact wall-clock time before
forcing power off. After recovery, inspect approximately five minutes on
either side of the incident for WHEA, display-driver, storage,
Kernel-Power, device-init and power-management events.
If the NVMe remains absent from Get-Disk or Event 11 / 129 recurs after
reseating, test the SSD in another known-good compatible M.2 slot,
external NVMe enclosure or another system where practical. Conversely,
test a known-good compatible NVMe in the Clevo slot if available. The
purpose is to distinguish drive failure from slot / motherboard / power
failure before replacing parts.
- title: "Perform NVRAM / CMOS retention test"
status: "pending"
text: >
Record BIOS date/time and relevant settings, fully power down, disconnect
AC for an extended interval, then boot directly into BIOS and verify
retention. If settings or time are lost, investigate the RTC/CMOS battery,
its connection and the motherboard RTC power path.
- title: "Preserve TPM / Measured Boot evidence"
status: "pending"
text: >
Keep the referenced MeasuredBoot JSON before any TPM, Secure Boot or
firmware reset operation. Do not clear the TPM solely as a diagnostic
experiment.
commands:
- 'C:\WINDOWS\Logs\MeasuredBoot\0000000053-0000000000.json'
- title: "Defer BIOS flashing"
status: "hold"
text: >
Do not flash BIOS/EC firmware while the machine has an unresolved
intermittent storage fault unless a later, model-specific remediation
path explicitly requires it and power/storage stability has first been
established.
closing: >
The 2026-09-14 diagnostic session establishes a substantially cleaner
software and filesystem baseline than the earlier investigation. Windows
corruption was found and repaired, and all completed post-repair validation
tests passed without reproducing the hard freeze. The investigation remains
open because no test has yet reproduced the original symptom and sustained
discrete-GPU, combined thermal/power and firmware-retention testing remain
outstanding. Before device-specific historical conclusions are reused, the
discrepancy between the September 4 Clevo inventory and the September 14
ASUS GA402RJ inventory must be reconciled.
At this checkpoint the Windows repair is complete and verified, while the
storage-path fault remains active and repeatable. The strongest evidence is
the coexistence of a currently enumerated PCIe Gen3 x4 NVMe controller,
failure of the 1 TB NVMe to appear in Get-Disk, and a fresh stornvme Event 11
on \Device\RaidPort2 during the 2026-09-14 session, backed by months of
historical Event 11 and Event 129 activity. The immediate priority is
preservation of data followed by physical M.2 inspection/reseat and controlled
device-versus-slot isolation. The firmware NVRAM/CMOS and TPM/Measured Boot
findings remain unresolved parallel tracks and should not yet be assumed to
share the same root cause.