# tiny-wb compatibility and operations
|
||
|
||
This guide describes the application as it exists today. It is intentionally
|
||
more conservative than “the firmware probably accepts it”: a range is called
|
||
supported only when tiny-wb selects the right path, decodes it knowingly, and
|
||
can represent it in the UI.
|
||
|
||
## Compatibility matrix
|
||
|
||
| Instrument/use | Status | Reason |
|
||
| --- | --- | --- |
|
||
| tinySA Basic low input, range wholly below 350 MHz | Best-supported path | The client sends `mode low input`, uses the Basic-oriented range, and normalizes raw samples with `zero 128`. |
|
||
| tinySA Basic high input, range wholly from 350 to 960 MHz | Implemented | The client sends `mode high input`; the RF path itself is less accurate and more overload-prone than low input. |
|
||
| tinySA Basic crossing from 240–<350 MHz into 350–960 MHz | Implemented as high input | The whole scan is forced onto the high path; the low path is not stitched to it. |
|
||
| Basic span starting below 240 MHz and ending at/above 350 MHz | Rejected | One physical path cannot cover it under the client's policy. Split it into scans. |
|
||
| tinySA Ultra/Ultra+ 0.1–800 MHz | Implemented; awaiting hardware qualification | Family detection, `mode low input`, automatic `zero 174` and readback verification. |
|
||
| Ultra+ ZS406 0.1–900 MHz | Hardware communications validated | Explicit ZS406/V0.4.6 identity permits the full normal-mode range; RF accuracy is not qualified. |
|
||
| Ultra+ ZS406 above 900 MHz through 5.4 GHz | Opt-in; hardware communications validated | Requires `scan.enable_ultra_mode = true`, sends `ultra on`, and verifies sweep readback. Expect slower scans, aliases/spurs and RF-port LO leakage. |
|
||
| ZS407 extended mode or any harmonic mode | Rejected | Their different ceilings and measurement behavior are not implemented. |
|
||
| Repeated-snapshot live display | Implemented; awaiting hardware qualification | `--live` retains a bounded 16-sweep history and one point buffer per derived hold/decay trace. It does not use native continuous framing. |
|
||
| Generator control, display capture, calibration, firmware update | Out of scope | No corresponding application workflow exists. |
|
||
|
||
At the exact 350 MHz boundary, the implementation's matching rules matter:
|
||
low accepts frequencies strictly below 350 MHz, while high accepts 350 MHz
|
||
through 960 MHz. A scan from 0 to exactly 350 MHz is rejected, but a scan from
|
||
240 to 350 MHz is assigned to the high path.
|
||
|
||
## Required equipment
|
||
|
||
- A genuine, powered tinySA Basic for the currently supported workflow.
|
||
- A data-capable USB cable. Charge-only cables do not enumerate a serial port.
|
||
- A host with permission to open the USB serial device.
|
||
- For conducted RF measurements: known-good 50-ohm coax/adapters, correctly
|
||
rated fixed attenuation, and a DC block when needed.
|
||
- For transmitter work: a suitable dummy load or sampler and power-rated
|
||
attenuation. Read the [safe-operation guide](tinysa-field-guide.md#safe-operation-read-before-connecting-a-signal)
|
||
before connecting a source.
|
||
|
||
Do initial software/serial testing with no external RF source connected. This
|
||
separates communications failures from unsafe or overloaded RF setups.
|
||
|
||
## Build and launch
|
||
|
||
Use a current stable Rust toolchain:
|
||
|
||
```console
|
||
cargo build --release
|
||
./target/release/tiny-wb
|
||
```
|
||
|
||
With no arguments the program starts the acquisition workflow. To inspect a
|
||
previous export without enumerating a serial device or starting acquisition,
|
||
open its renderer directly:
|
||
|
||
```console
|
||
./target/release/tiny-wb --view scan.csv
|
||
# A positional path is equivalent: ./target/release/tiny-wb scan.csv
|
||
```
|
||
|
||
Run it from the working directory for your settings and output, or set
|
||
`TINY_WB_CONFIG` to another configuration path. See [configuration](configuration.md).
|
||
|
||
For live display, launch:
|
||
|
||
```console
|
||
./target/release/tiny-wb --live
|
||
```
|
||
|
||
Select the connection and scan parameters normally. The configured Points value
|
||
is the fixed size of every live sweep and visible/exported trace. tiny-wb opens
|
||
one connection, configures it once, and requests repeated complete `scanraw`
|
||
snapshots. This deliberately avoids firmware continuous framing until abort and
|
||
stream-resynchronization behavior is verified on supported hardware.
|
||
|
||
### Serial permissions
|
||
|
||
On Linux, identify the device after plugging it in:
|
||
|
||
```console
|
||
ls -l /dev/ttyACM*
|
||
```
|
||
|
||
The exact permission mechanism is distribution-specific (often a `dialout` or
|
||
`uucp` group, or a udev rule). Do not solve it by running the RF application as
|
||
root when a scoped device permission is available.
|
||
|
||
On Windows, use Device Manager to find the COM port. Close serial terminals and
|
||
other tinySA applications before launching tiny-wb; only one process can
|
||
normally own the port.
|
||
|
||
## User interface
|
||
|
||
### Connection screen
|
||
|
||
The application enumerates ports at startup. Selection priority is:
|
||
|
||
1. the port saved in `config.toml`, if present;
|
||
2. the configured `serial.preferred_ports` (by default `/dev/ttyACM0`, `COM3`, `COM5`, `/dev/ttyS16`);
|
||
3. the first enumerated port.
|
||
|
||
Default baud choices range from 19,200 to 3,000,000, with 115,200 selected.
|
||
`serial.baudrates` defines the choices; the selected rate must belong to that
|
||
list. No available ports produces an actionable error rather than an index panic.
|
||
|
||
### Scan screen
|
||
|
||
The embedded defaults are shown below. Steps and sample/repeat bounds are
|
||
configurable; Basic frequency limits remain fixed protocol rules.
|
||
|
||
| Field | Unit | Default | Step | Bounds |
|
||
| --- | --- | ---: | ---: | ---: |
|
||
| Start frequency | MHz | 240 | 10 | 0–5,400 (model checked after identity) |
|
||
| Stop frequency | MHz | 800 | 10 | 10–5,400 (model checked after identity) |
|
||
| Points | samples | 10,001 | 100 | 101–1,000,001 |
|
||
| Repeat | measurements/point | 1 | 1 | 1–1,000 |
|
||
|
||
Left/right or `h`/`l` changes the selected field. Up/down or `k`/`j` changes
|
||
the selection/value. On either frequency field or the Points field, typing a
|
||
digit opens an inline editor: digits append, Backspace removes a digit, Enter
|
||
applies a value within the displayed bounds, and Escape cancels the edit.
|
||
Frequencies are entered in MHz; points are entered as a sample count. Applying
|
||
a typed value does not advance, so press Enter again to start the scan. Outside
|
||
the editor, Enter advances to the next screen and `q` or Escape exits.
|
||
|
||
Instrument identification sends the read-only `version` and `info` queries. If
|
||
the first complete pair is empty or cannot identify a supported family, tiny-wb
|
||
repeats that pair once on the same connection. If both exchanges are empty or
|
||
unrecognized, the terminal application's single-scan and live workers close the
|
||
connection, discard their buffered replies, reopen once, and repeat identification
|
||
automatically. The UI briefly reports `Reconnecting after failed identification`.
|
||
A successful retry proceeds with the original settings; a second failed connection
|
||
reports its error. This recovery occurs before scan settings are changed or CSV
|
||
output is created.
|
||
|
||
Conflicting model identities, connection-opening failures, transport timeouts,
|
||
incomplete prompts, and failures during configuration/acquisition do not trigger
|
||
a reconnect. This avoids replaying a scan after a possible device mutation.
|
||
Library callers of `acquire`/`acquire_live` retain ownership of their connection
|
||
and only get the existing same-connection identity retry.
|
||
|
||
The reconnect addresses a user-reported Linux first-open failure where a manual
|
||
retry works. Stale serial input is a possible cause, not a verified diagnosis;
|
||
there is no new operating-system buffer purge or firmware-specific workaround.
|
||
Regression transcripts cover this recovery, but the intermittent first-open
|
||
hardware failure has not been reproduced locally.
|
||
|
||
Large point and repeat values can produce extremely long scans. Total time also
|
||
depends on RBW and instrument mode; the progress bar is based mainly on bytes
|
||
received, not a predictive time estimate.
|
||
|
||
### Progress and result
|
||
|
||
The scan runs on a worker thread while the UI displays shared progress and the
|
||
concatenated `version`/`info` response. On success, the final screen plots a
|
||
scatter trace. Its Y axis defaults to −128–0 dBm and uses the configured `ui.chart_min_dbm`
|
||
and `ui.chart_max_dbm` bounds. Values outside those bounds are clipped visually
|
||
even though CSV data may contain them.
|
||
|
||
The frequency axis is labeled in MHz. In completed plots and live mode, `+` or
|
||
`=` zooms in, `-` zooms out, Left/Right or `h`/`l` pans by a quarter of the
|
||
visible span, and `0` or Home restores the full range. Zoom and pan stay within
|
||
the frequencies present in the plot. Maximum zoom follows the finest positive
|
||
sample spacing in the loaded data, and frequency labels add decimal places as
|
||
the visible range narrows. `m` toggles a top-right box containing the level and
|
||
frequency of the strongest sample in the visible range.
|
||
After an acquired scan, `r` reconnects and repeats the exact request and settings
|
||
without reopening the parameter screen; each successful repeat creates a new
|
||
collision-safe CSV. `n` returns to the scan screen with the previous parameters
|
||
prefilled so they can be edited before starting another scan. These restart keys
|
||
are not available when viewing a CSV directly. Plot bindings are configurable
|
||
under `[ui.bindings]`; on acquired results, `r` and `n` take precedence over any
|
||
matching plot binding. `q`, Escape, or Enter exits the renderer.
|
||
|
||
### Live display
|
||
|
||
Live mode updates the plot only after a complete, validated sweep. Its host-side
|
||
calculation keys are:
|
||
|
||
| Key | Visible buffer |
|
||
| --- | --- |
|
||
| `1` | Rolling arithmetic average of up to 4 sweeps |
|
||
| `2` | Rolling arithmetic average of up to 16 sweeps |
|
||
| `3` | Maximum held at each frequency since live capture began |
|
||
| `4` | Maximum with a 1 dB fall per completed sweep, limited by the new value |
|
||
| `5` | Minimum held at each frequency since live capture began |
|
||
| `6` | Minimum with a 1 dB rise per completed sweep, limited by the new value |
|
||
|
||
The history is bounded to 16 complete sweeps regardless of run duration. Hold
|
||
and decay calculations retain one value per configured point. `s` writes the
|
||
currently selected buffer to a new collision-safe CSV while capture continues.
|
||
`q`, Escape, or Enter requests a stop; the current sweep is allowed to finish,
|
||
the instrument receives `resume`, the selected buffer is saved, and the program
|
||
exits. A transport failure is reported rather than exporting a partial frame.
|
||
|
||
Subtraction/reference-buffer processing is not implemented yet. The live modes
|
||
are host calculations over repeated snapshots, not claims about the firmware's
|
||
front-panel detector or trace modes, and require physical-device qualification.
|
||
|
||
## Files
|
||
|
||
### `config.toml`
|
||
|
||
The current selection is saved before acquisition starts:
|
||
|
||
```toml
|
||
port = "/dev/ttyACM0"
|
||
baudrate = 115200
|
||
start_frequency = 240
|
||
stop_frequency = 960
|
||
points = 10001
|
||
repeat = 1
|
||
```
|
||
|
||
Frequencies in this file are MHz, unlike protocol frequencies (Hz). Saving a selection atomically replaces this file while preserving every
|
||
recognized settings section. Missing files use embedded defaults; malformed,
|
||
unknown or invalid settings are reported before terminal startup. Override the
|
||
path with `TINY_WB_CONFIG`. See [configuration](configuration.md) for the schema.
|
||
|
||
### CSV
|
||
|
||
By default the scanner writes `scan_YYYYMMDD HH_MM_SS_microseconds_counter.csv`
|
||
in the working directory. The directory and filename prefix are configurable;
|
||
exclusive creation prevents overwriting earlier scans. The default has no header:
|
||
|
||
```csv
|
||
240,-92.4375
|
||
240.072,-91.96875
|
||
```
|
||
|
||
Column one is MHz and column two is dBm. The file is created only after complete frame validation and a successful
|
||
resume response. Failed writes are reported and incomplete files are removed
|
||
when possible. Enable `output.include_header` for named columns. Choose the
|
||
frequency-label convention explicitly after reviewing the
|
||
[frequency assignment notes](usb-protocol.md#frequency-assignment).
|
||
The direct renderer accepts this header or headerless files, ignores blank
|
||
lines, and reports malformed, non-finite, empty, or decreasing-frequency data
|
||
with its CSV line number before initializing logging or taking over the terminal.
|
||
|
||
### Logs
|
||
|
||
`flexi_logger` uses `logging.filter` and `logging.directory`; defaults are
|
||
`info` and the working directory. The filter also applies in release builds. Logs
|
||
can contain instrument version/configuration details and port names. Attach the
|
||
relevant bounded excerpt—not an uncontrolled archive—when reporting a bug.
|
||
|
||
## Instrument state changed by a run
|
||
|
||
tiny-wb changes repeat count, raw zero offset, input mode, display sweep start
|
||
and stop, and pause/resume state. By default it also runs the legacy auxiliary textual scan before
|
||
the raw scan; `scan.legacy_pre_scan` can disable it after hardware validation. It does not snapshot and restore previous values. If preserving a
|
||
carefully tuned front-panel configuration matters, save it as an instrument
|
||
preset and reload it after tiny-wb exits.
|
||
|
||
After attempting `pause`, acquisition always attempts `resume`, including on
|
||
frame or I/O errors. This is best-effort recovery, not confirmation that a
|
||
disconnected device resumed or that its previous settings were restored. Quitting
|
||
during acquisition can still terminate the worker before recovery. Send `resume`, use the UI, or
|
||
power-cycle/reload a preset after making the RF setup safe.
|
||
|
||
## Troubleshooting
|
||
|
||
### No serial port is listed
|
||
|
||
- Confirm the device is powered on and the cable supports data.
|
||
- Try a direct USB port or known USB 2.0 hub/cable.
|
||
- Check OS device enumeration before debugging tiny-wb.
|
||
- On Linux, inspect `/dev/ttyACM*` and kernel logs; on Windows, Device Manager.
|
||
|
||
### Port cannot be opened
|
||
|
||
- Close other serial terminals and tinySA software.
|
||
- Check the selected COM/TTY name and user permissions.
|
||
- Unplug/reconnect if the device was just in DFU mode; DFU and CDC serial are
|
||
different USB personalities.
|
||
|
||
### Unsupported device identity on first connection
|
||
|
||
The application automatically reopens once after repeated empty or unknown
|
||
identity replies; see [identification recovery](#scan-screen). If it still
|
||
fails, confirm the port and instrument model. Do not assume that every unknown
|
||
device is a tinySA. Include the final error and firmware details in a bug report.
|
||
|
||
### “No version found” or a timeout
|
||
|
||
- Verify the selected port is the tinySA, not another CDC device.
|
||
- Wake/power the instrument and close auto-refreshing software.
|
||
- Manually send `version` in a serial terminal and confirm a `ch>` prompt.
|
||
- Record firmware version. The client relies on prompt timing and may fail on a
|
||
slow command when the configured read timeout is too short. Fragmented prompts
|
||
are handled by the buffered transport.
|
||
|
||
### Parse beginning/end/alignment error
|
||
|
||
- Reduce point count and repeat to minimize transfer time.
|
||
- Disable any other process reading the port.
|
||
- Ensure the firmware implements the documented `scanraw` framing.
|
||
- Preserve a raw byte capture if possible. Do not convert it through UTF-8.
|
||
- The decoder now rejects truncated, extra, misaligned and unterminated records.
|
||
Preserve the exact requested point count and firmware version with the capture.
|
||
|
||
### Trace is shifted in frequency
|
||
|
||
The default `firmware` labeling reproduces the reviewed `scanraw` integer and
|
||
single-precision arithmetic. If a saved configuration selects `inclusive`, it
|
||
uses `points - 1` intervals and can shift later labels by nearly one firmware
|
||
step. Remove that override or choose `scan.frequency_axis = "firmware"`, then
|
||
verify with a known narrow carrier and record the firmware version. The setting
|
||
changes CSV/chart labels; it does not change the instrument request or calibrate
|
||
the analyzer.
|
||
|
||
### Levels are wrong by about 46 dB
|
||
|
||
That is the difference between Ultra's documented default raw offset (174) and
|
||
Basic's (128). The application and hardware validator now select the detected
|
||
family's native offset automatically and verify its readback. A 46 dB shift
|
||
suggests that the configured command/decoder offset does not match the firmware
|
||
value. Stop treating the result as calibrated data and capture `version`,
|
||
`info`, and the `zero` command response. This bias is numeric encoding, not
|
||
model-specific record padding.
|
||
|
||
### Unexpected harmonics or spurs
|
||
|
||
Assume overload or an image until disproved. Add attenuation, reduce span,
|
||
change RBW, use a filter/preselector, and compare paths where possible. Consult
|
||
the [measurement controls](tinysa-field-guide.md#measurement-controls-and-trade-offs).
|
||
|
||
## Reproducible bug report checklist
|
||
|
||
Include:
|
||
|
||
- tiny-wb commit hash shown in the title;
|
||
- host OS and serial port type;
|
||
- exact tinySA model/rear label;
|
||
- `version`, `info`, and relevant `help` output;
|
||
- start/stop, points, repeat, and selected baud;
|
||
- RF setup, attenuation, DC block, expected maximum level, RBW, LNA, and Ultra
|
||
mode state where relevant;
|
||
- the smallest CSV/log excerpt that demonstrates the problem;
|
||
- whether the front panel was paused and whether `resume` recovered it.
|
||
|
||
Never include a dangerous live-transmitter reproduction just to demonstrate a
|
||
software bug; substitute a low-level known source or recorded serial fixture.
|
||
|
||
## Remaining engineering work
|
||
|
||
ZS407 extended detection, harmonic ranges above 5.4 GHz, overall
|
||
transaction deadlines, cancellation/abort, full instrument-state restoration,
|
||
and richer output metadata remain open. Buffered framing, strict record-count
|
||
validation, reusable core interfaces and hardware-free regression tests are
|
||
implemented. Real Basic/Ultra transcript fixtures and hardware checks are still
|
||
needed; see [architecture](architecture.md#extension-points-and-remaining-limits).
|
||
|
||
## Hardware-free operation
|
||
|
||
Use the [mock server](mock-device.md) with the TCP connection backend to run
|
||
the normal acquisition and CSV workflow without USB hardware. The production
|
||
app supports the common Ultra normal range; see [support scope](ultra-support.md).
|