Application configuration
config/default.toml is the authoritative, commented set of defaults embedded
in the binary at compile time. To customize them, copy it to config.toml in
the working directory, or supply a partial file containing only overrides.
Rebuild after changing the embedded file; it is not read at runtime.
At startup the application reads config.toml, or the path named by the
TINY_WB_CONFIG environment variable. For example:
TINY_WB_CONFIG=/path/to/session.toml cargo run --release
Settings and logging are validated before entering the terminal interface. Saving a scan selection writes to this same path; unrelated configuration sections are retained. An invalid file is reported rather than silently reset.
The configuration API is in src/config.rs. It recursively merges supplied
TOML tables with the embedded defaults, deserializes into typed settings, and
validates before use. Arrays replace their defaults. Unknown keys, invalid
numbers, malformed files and I/O failures are errors; only an absent file uses
defaults. The original six top-level keys remain compatible:
port = "/dev/ttyACM0"
baudrate = 115200
start_frequency = 240
stop_frequency = 960
points = 10001
repeat = 1
Start/stop frequencies are MHz. The Basic envelope remains 0–960 MHz,
with stop at least 10 MHz; the protocol separately rejects spans that cannot
use one input path. Values must be ordered. The selected baud rate must be in
serial.baudrates; points and repeat must fit the configured bounds.
| Section | Settings and units |
|---|---|
serial |
Read timeout and command/settling/pre-scan delays in milliseconds; bounded text response size in bytes; baud-rate choices and preferred ports. |
scan |
Raw zero offset in dB, frequency/sample keyboard steps, sample/repeat limits, frequency-axis convention, and legacy pre-scan toggle. |
ui |
Event polling interval in milliseconds and finite increasing chart bounds in dBm. |
output |
CSV directory, filename prefix, and optional column header. |
logging |
Logger filter expression and destination directory. |
scan.device_model = "auto" detects the family before changing settings.
scan.auto_zero_offset = true selects Basic 128 or Ultra 174 and verifies the
zero readback. To retain a manual scan.zero_offset, set automatic selection
to false. See support and migration. The wire record has no
model-specific padding; see level conversion.
For example, this partial file changes the serial timeout and output format while retaining the default scan selection:
[serial]
timeout_ms = 5000
[output]
directory = "scans"
filename_prefix = "measurement"
include_header = true
All relative paths are relative to the process working directory. Saving a selection preserves every recognized section, using a same-directory temporary file, flush, and rename. The old configuration survives validation or write failure. TOML formatting and comments are not preserved; retain comments in a separate template if needed. The configuration file's parent must exist.
scan.frequency_axis = "firmware" is the default. It reproduces the reviewed
scanraw integer division, single-precision multiplication and conversion back
to integer Hz. "inclusive" preserves the legacy tiny-wb labels
(span / (points - 1)) and includes the requested stop frequency. Neither
setting changes the request or proves RF frequency accuracy. Existing saved
files that explicitly contain frequency_axis = "inclusive" keep their old
labels; partial configurations that omit the key adopt the corrected default.
See frequency assignment.
The preparatory scan START STOP 290 101 remains enabled by default with
scan.legacy_pre_scan = true for compatibility. Its undocumented output mask
is not a tunable protocol contract. Disable the step only after checking the
target instrument; hardware validation remains necessary.
Protocol delimiters, fixed-point scaling, command grammar and Basic input-path limits remain code invariants. Configuration cannot turn a Basic-only client into an Ultra-compatible one by increasing a numeric limit.
Connection backends
[connection] backend = "serial" preserves USB behavior. Select "tcp" with
tcp_address = "127.0.0.1:7355" and tcp_timeout_ms = 3000 for an explicit
mock/bridge. The address must be numeric IPv4/IPv6 with a nonzero port; timeout
is 1–600,000 ms and applies to connect/read/write operations. All backend fields
are validated, including inactive ones. TCP bypasses USB enumeration and ignores
serial port/baud selections; protocol pacing still uses [serial] timing fields.
See the mock client template and mock guide.