# Application configuration
|
||
|
||
`config/default.toml` is the authoritative, commented set of defaults embedded
|
||
in the binary at compile time. To customize them, copy it to `config.toml` in
|
||
the working directory, or supply a partial file containing only overrides.
|
||
Rebuild after changing the embedded file; it is not read at runtime.
|
||
|
||
At startup the application reads `config.toml`, or the path named by the
|
||
`TINY_WB_CONFIG` environment variable. For example:
|
||
|
||
```console
|
||
TINY_WB_CONFIG=/path/to/session.toml cargo run --release
|
||
```
|
||
|
||
Settings and logging are validated before entering the terminal interface.
|
||
Saving a scan selection writes to this same path; unrelated configuration
|
||
sections are retained. An invalid file is reported rather than silently reset.
|
||
|
||
The configuration API is in `src/config.rs`. It recursively merges supplied
|
||
TOML tables with the embedded defaults, deserializes into typed settings, and
|
||
validates before use. Arrays replace their defaults. Unknown keys, invalid
|
||
numbers, malformed files and I/O failures are errors; only an absent file uses
|
||
defaults. The original six top-level keys remain compatible:
|
||
|
||
```toml
|
||
port = "/dev/ttyACM0"
|
||
baudrate = 115200
|
||
start_frequency = 240
|
||
stop_frequency = 960
|
||
points = 10001
|
||
repeat = 1
|
||
```
|
||
|
||
Start/stop frequencies are **MHz**. The Basic envelope remains 0–960 MHz,
|
||
with stop at least 10 MHz; the protocol separately rejects spans that cannot
|
||
use one input path. Values must be ordered. The selected baud rate must be in
|
||
`serial.baudrates`; points and repeat must fit the configured bounds.
|
||
|
||
| Section | Settings and units |
|
||
| --- | --- |
|
||
| `serial` | Read timeout and command/settling/pre-scan delays in milliseconds; bounded text response size in bytes; baud-rate choices and preferred ports. |
|
||
| `scan` | Raw zero offset in dB, frequency/sample keyboard steps, sample/repeat limits, frequency-axis convention, and legacy pre-scan toggle. |
|
||
| `ui` | Event polling interval in milliseconds and finite increasing chart bounds in dBm. |
|
||
| `output` | CSV directory, filename prefix, and optional column header. |
|
||
| `logging` | Logger filter expression and destination directory. |
|
||
|
||
`scan.device_model = "auto"` detects the family before changing settings.
|
||
`scan.auto_zero_offset = true` selects Basic 128 or Ultra 174 and verifies the
|
||
`zero` readback. To retain a manual `scan.zero_offset`, set automatic selection
|
||
to false. See [support and migration](ultra-support.md). The wire record has no
|
||
model-specific padding; see [level conversion](usb-protocol.md#level-conversion-and-zero).
|
||
|
||
For example, this partial file changes the serial timeout and output format
|
||
while retaining the default scan selection:
|
||
|
||
```toml
|
||
[serial]
|
||
timeout_ms = 5000
|
||
|
||
[output]
|
||
directory = "scans"
|
||
filename_prefix = "measurement"
|
||
include_header = true
|
||
```
|
||
|
||
All relative paths are relative to the process working directory. Saving a
|
||
selection preserves every recognized section, using a same-directory temporary
|
||
file, flush, and rename. The old configuration survives validation or write
|
||
failure. TOML formatting and comments are not preserved; retain comments in a
|
||
separate template if needed. The configuration file's parent must exist.
|
||
|
||
`scan.frequency_axis = "firmware"` is the default. It reproduces the reviewed
|
||
`scanraw` integer division, single-precision multiplication and conversion back
|
||
to integer Hz. `"inclusive"` preserves the legacy tiny-wb labels
|
||
(`span / (points - 1)`) and includes the requested stop frequency. Neither
|
||
setting changes the request or proves RF frequency accuracy. Existing saved
|
||
files that explicitly contain `frequency_axis = "inclusive"` keep their old
|
||
labels; partial configurations that omit the key adopt the corrected default.
|
||
See [frequency assignment](usb-protocol.md#frequency-assignment).
|
||
|
||
The preparatory `scan START STOP 290 101` remains enabled by default with
|
||
`scan.legacy_pre_scan = true` for compatibility. Its undocumented output mask
|
||
is not a tunable protocol contract. Disable the step only after checking the
|
||
target instrument; hardware validation remains necessary.
|
||
|
||
Protocol delimiters, fixed-point scaling, command grammar and Basic input-path
|
||
limits remain code invariants. Configuration cannot turn a Basic-only client
|
||
into an Ultra-compatible one by increasing a numeric limit.
|
||
|
||
## Connection backends
|
||
|
||
`[connection] backend = "serial"` preserves USB behavior. Select `"tcp"` with
|
||
`tcp_address = "127.0.0.1:7355"` and `tcp_timeout_ms = 3000` for an explicit
|
||
mock/bridge. The address must be numeric IPv4/IPv6 with a nonzero port; timeout
|
||
is 1–600,000 ms and applies to connect/read/write operations. All backend fields
|
||
are validated, including inactive ones. TCP bypasses USB enumeration and ignores
|
||
serial port/baud selections; protocol pacing still uses `[serial]` timing fields.
|
||
See the [mock client template](../config/mock-client.toml) and [mock guide](mock-device.md).
|